EasyManua.ls Logo

Burstner Nexxo Time T 569 - User Manual

Burstner Nexxo Time T 569
274 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Instruction manual
T-Modell - 17/18 - Ausgabe 09/17 - 2891569 - BUE-0029-19EN
© 2017 Bürstner GmbH & Co. KG Kehl
Instruction manual
Dear Reader ...
We would like to congratulate you on the purchase of your new motorhome. You have selected a top-quality
vehicle which will afford you many years of enjoyment.
To enable you to always use and operate your motorhome properly and easily, your Bürstner dealer will first
provide you detailed instructions for all important functions when you take delivery.
This manual, the instruction manuals from the base vehicle manufacturer as well as the instruction manuals
from the appliance manufacturer will always be at hand to answer any questions you may have regarding your
motorhome.
Before your first journey
Please familiarise yourself with this manual rather than relying on it strictly for reference.
Fill in the warranty cards for the appliances and special equipment in the individual instructions and send these
cards to the respective manufacturers. This ensures your warranty claim for each appliance.

Table of Contents

Questions and Answers

  • H
    Heidi MckayAug 17, 2025
    What to do if my Burstner Nexxo Time T 569 Motorhomes living area battery is overloaded ('hot')?
    • P
      petersenashleyAug 17, 2025
      If the living area battery in your Burstner Motorhomes is overloaded or 'hot', consider these steps: * Check the battery selection switch and move its position if it is set wrongly. * Ensure the battery cut-off switch on the transformer/rectifier is switched on. * If the living area battery is discharged, charge it. * Inspect the jumbo flat fuse (50 A) on the living area battery and replace it if it is defective.
  • D
    Dominique FuentesAug 19, 2025
    Why is my Burstner Nexxo Time T 569 air conditioning unit not starting up?
    • M
      Matthew JeffersonAug 19, 2025
      The air conditioning unit in your Burstner Motorhomes might not start due to several reasons: * There is no 230 V power supply. Connect the vehicle to the local power supply. * The 230 V automatic circuit breaker has triggered. Switch on the 230 V automatic circuit breaker. * The remote control batteries are empty. Change the remote control batteries. * There is an obstacle between the remote control and the IR receiver. Remove the obstacle. * The temperature has been set incorrectly. Adjust the temperature.
  • C
    Caitlin KeithAug 22, 2025
    What to do if road light system or interior lighting does no longer work correctly in my Burstner Nexxo Time T 569?
    • J
      Justin WoodsAug 22, 2025
      If the road light system or interior lighting in your Burstner Motorhomes is not working correctly, it could be due to several reasons: * A bulb is defective. Replace the bulb, noting the volts and watts specifications. * The fuse on the transformer/rectifier is defective. Replace the fuse on the transformer/rectifier.
  • A
    Angela KimAug 25, 2025
    What to do if my Burstner Nexxo Time T 569 Motorhomes heater does not ignite?
    • A
      Amanda GonzalesAug 26, 2025
      If the heater in your Burstner Motorhomes does not ignite, check the following: * Ensure there is enough gas by opening the regulator tap and gas isolator tap. * Check the battery voltage and charge the battery if it is too low. The heater should switch on automatically if the battery voltage rises above 11 V. * Verify that there is a 230 V power supply and connect it if necessary.
  • J
    Juan LeblancAug 28, 2025
    What to do if I have no gas in my Burstner Motorhomes?
    • G
      George VillarrealAug 28, 2025
      If you have no gas in your Burstner Motorhomes, check the following: * Ensure the gas bottle is not empty; change it if needed. * Make sure the gas isolator tap is open. * Check that the regulator tap on the gas bottle is open.
  • L
    lindseyyoungAug 30, 2025
    What to do if the 12 V indicator lamp does not light up or the extractor hood does not work in my Burstner Nexxo Time T 569 Motorhomes?
    • M
      Matthew GlassAug 30, 2025
      If the 12 V indicator lamp does not light up or the extractor hood does not work in your Burstner Motorhomes, try the following: * Ensure the 12 V power supply is switched on. * Check that the battery cut-off switch on the transformer/rectifier is on. * Charge the starter or living area battery if they are not charged. * Replace the flat fuse (2 A) in the living area battery if it is defective. * Replace the fuse (15 A) at the transformer/rectifier if it is defective.
  • A
    Amber RobertsSep 2, 2025
    Why am I not getting a satellite signal and seeing a black screen on my Burstner Nexxo Time T 569 Motorhomes?
    • J
      Jennifer SmithSep 2, 2025
      If you're experiencing a black screen and no satellite signal in your Burstner Motorhomes, it could be due to a few reasons: * Ensure that there are no obstacles in front of the satellite unit towards the south. * Verify that the correct satellite has been selected.
  • C
    Colleen WileySep 5, 2025
    Why won't my Burstner Nexxo Time T 569 Motorhomes satellite unit switch on?
    • S
      Shelby CharlesSep 5, 2025
      The satellite unit in your Burstner Motorhomes might not switch on if: * The vehicle engine is running. Switch the vehicle engine off. * The remote control battery is empty. Change the battery. * The fuse on the supply cable is damaged. Replace the fuse.
  • C
    cmartinezSep 7, 2025
    What to do if I find leakage water inside my Burstner Nexxo Time T 569?
    • L
      Lisa AndrewsSep 7, 2025
      If you find leakage water inside your Burstner Motorhomes: * Identify and fix the leak, and re-connect any loose water pipes. * Replenish drinking water if the water tank is empty. * Ensure the drain cock is closed.
  • H
    Holly ScottSep 12, 2025
    Why is my Burstner Motorhomes microwave oven not cutting in?
    • J
      Justin MullenSep 12, 2025
      If the microwave oven in your Burstner Motorhomes is not working, check the following: * Replace the fuse if it is defective. * Ensure the door of the microwave oven is properly closed, removing any obstructions.

Summary

Safety Instructions

Fire Prevention and Safety

Instructions for avoiding fire risks and fire-fighting procedures.

Road Safety Precautions

Safety checks and precautions before driving the motorhome.

Before the Journey

Vehicle Payload and Loading Guidelines

Guidelines on vehicle loading, weight distribution, and payload calculation.

During the Journey

Motorhome Driving Instructions

Instructions and safety tips for operating the motorhome while driving.

Seat Belt Usage and Safety

Guidelines for correct seat belt usage and fastening.

Child Restraint System Guidelines

Instructions on securing children with appropriate restraint systems.

Gas System

General Gas System Safety

General safety instructions and responsibilities for the vehicle's gas system.

Gas Bottle Handling and Connection

Instructions for handling, transporting, and connecting gas bottles.

Electrical System

General Electrical System Safety

Safety precautions when working with the vehicle's electrical system.

Vehicle Appliances

Heater and Boiler Operation

Instructions for operating the heater and boiler, including initial start-up.

Gas Cooker Operation and Safety

Safety instructions and operating procedures for the gas cooker.

Sanitary Fittings

Maintenance Procedures

Wheels and Tyres

Wheel Changing Procedure

Step-by-step instructions for safely changing a vehicle wheel.

Correct Tyre Pressure Guidelines

Importance of correct tyre pressure and how to check it for safety.

Troubleshooting Vehicle Issues

Gas System Fault Diagnosis

Troubleshooting common gas system faults like no gas or blocked inlets.

Special Equipment Weight Details

Vehicle Inspection Plan

Burstner Nexxo Time T 569 Specifications

General IconGeneral
ModelNexxo Time T 569
Length5.99 m
Width2.30 m
Seatbelts4
Waste Water Tank Capacity90 l
Max Weight3500 kg

Related product manuals