88 (98)
any naked ames and cigarettes before lling the fuel tank. Do not operate any
electrical equipment while lling the fuel tank.
Boats with xed fuel tanks have a lling hole located on the taffrail on the right
side of the boat. The Buster Cabin, X, Lx, and L Pro have visible lling holes.
Other Buster models have lling holes beneath the cover of the lockable rope box.
Detachable tanks must be lifted out of the boat for lling to ensure that fuel is not
able to spill into the bilge if the tank is overlled.
If you refuel your boat at a petrol station, do not use a plastic funnel that prevents
the static charge between the pistol and the ller hole from discharging. After you
have lled the tank, make sure that no fuel has spilled into the bilge and clean up
any splashes of fuel immediately (see Fuel Tank Volume; Appendix 2: Technical
specications).
There is space for the detachable fuel tank on the Buster L, M, Mcc, S, Scc, XS,
XSr, and Mini beneath the aft bench in the cockpit. The Buster L, M, and Mcc also
have space for a second tank. Do not store spare tanks in unventilated spaces or
unsecured. Equipment that contains fuel may only be stored in compartments that
are designed for the purpose.
Check the fuel lines annually for wear and tear. The locations of fuel system
components are presented in Appendix 3.
5.7.2 Fire-ghting and re protection
The Buster Magnum M5, Magnum Pro, SuperMagnum, Magnum, Cabin, XXL, XL,
XL Pro, XLe, X, Le, Lx, L Pro, L, M, and Mcc are equipped with a 2 kg category
32A68B powder re extinguisher as described in Appendix 3. On these boats, the
re extinguisher is located on the left side of the storage area in the bow of the boat.
On the Buster Cabin, the re extinguisher is located in the front-left of the covered
cockpit. On the Buster XLe Convertible, the re extinguisher is beneath the rear
bench on the right side of the boat. On the Buster XLe, the re extinguisher is by the
operator's feet. On the Buster Le, the re extinguisher is by the passenger's feet.
The location of the extinguisher is indicated by a symbol that is visible in the cockpit.
All re extinguishers are subject to annual inspection. Fire extinguishers older than
10 years must also pass a pressure test. If the original re extinguisher is replaced,
the minimum extinguishing capacity of the new extinguisher must be 8A 68B
Always ensure that all re-ghting equipment is easily accessible, whether the boat
is empty or loaded. Advise all crew members of the location and correct operation of
the re-ghting equipment.
Make sure that no fuel spills into the bilge and check the boat for fuel leaks at
regular intervals. The smell of petrol is a clear sign of a fuel leak.