PRODUCT INFORMATION
BULLETIN
105 Bonnie Drive
Butler, PA 16002
724-283-4681
724-283-5939 (fax)
www.bwieagle.com
AIR-EAGLE
®
XLT
900 MHz RF Receiver
MODEL 441-8000-R1NC-DC
DESCRIPTION
The AIR-EAGLE XLT is an RF system designed for medium to long range
wireless remote control of electrical apparatus in a variety of industrial
applications. Systems can consist of any number of receivers and
handheld or contact input transmitters working together. This receiver is
equipped with 4 independent relays that can switch 5 amps @ 120VAC or
30VDC. The relays are user programmable for momentary or
toggle/latching operation and can be directly interfaced with the
customer's equipment or P.L.C. Seven user selectable frequencies allow
multiple systems to be used in the same area. Capable of receiving
remote signals transmitted from up to 2500 feet away (with the handheld
transmitter) or up to 2 miles away (with the contact input transmitter), the
Air-Eagle XLT utilizes spread-spectrum technology and provides the
utmost security and reliability even in the noisiest RF environments.
SERIES FEATURE
The “441” Series features repeating capability. Transmitters can be set
up to send “repeat signal packets”, and any transmitter or receiver
within its range will repeat the signal packet to help propagate
communication over widespread areas.
APPROVALS
United States (FCC)
MCQ-XB900HP
Canada (IC)
1846A-XB900HP
INSTALLATION
DISCONNECT DC Power from all equipment before installation.
1. Mount the AIR-EAGLE XLT RECEIVER in a convenient location.
2. Install relay wiring to terminal strip.
3. Install antenna onto connector located on the right side on the
enclosure.
4. Connect supplied power input cable to your external power source.
TERMINAL STRIP WIRING
N/O Relay #1
7
N/O Relay #3
13
(-) 9-36VDC INPUT
C Relay #1
8
C Relay #3
14
(+) 9-36VDC INPUT
N/C Relay #1
9
N/C Relay #3
N/O Relay #2
10
N/O Relay #4
C Relay #2
11
C Relay #4
N/C Relay #2
12
N/C Relay #4
Relay #1 contacts are shown in their de-energized state. When power is
applied to the unit, relay #1 will energize. The relay will then de-energize
when a signal is received from the transmitter.
Dimensions (with mounting plate) 6.3L x 4.8” W x 2.3 H
CONTROLS AND INDICATORS
.
LED1
Illuminated when power is applied to receiver
LED2
Illuminated when relay #1 is energized
LED3
Illuminated when relay #2 is energized
LED4
Illuminated when relay #3 is energized
LED5
Illuminated when relay #4 is energized
RF1
RF module that receives data from the remote
transmitter
REL1 thru REL4
Four SPDT output control relays
SEL1
Seven dip switches for selecting relay options
and operating frequency
Question and Answer IconNeed help?

Do you have a question about the BWI Eagle AIR-EAGLE XLT 441-8000-R1NC-DC and is the answer not in the manual?

Summary

Product Description and Features

Product Description

Overview of the AIR-EAGLE XLT RF system for industrial remote control applications.

Series Feature

Details the '441' Series repeating capability for extending communication range.

Approvals and Installation

Approvals

Lists FCC and IC approval numbers for the AIR-EAGLE XLT receiver.

Installation Instructions

Steps for safely mounting and connecting the AIR-EAGLE XLT receiver.

Controls and Indicators

LED Indicators

Explanation of LED status for power and relay energization.

RF Module

Description of the RF1 module for receiving data.

Relay Outputs

Details on the four SPDT output control relays (REL1-REL4).

Selector Switch

Function of the SEL1 dip switches for configuration.

Terminal Strip Wiring

Relay and Frequency Configuration

Relay Configuration Setup

Instructions for setting relay operation (momentary/toggle) using SW1-SW4.

Frequency Set-Up

Instructions for selecting operating frequency using SW5-SW7.

Accessories and Specifications

Available Accessories

List of optional antennas and cables for the system.

Technical Specifications

Key technical details including power, range, frequency, and environment.

Limited Warranty Statement

Relay Output Wiring Examples

Internal Relay Wiring

Wiring loads less than 5 Amps directly to internal relays.

External Relay Wiring

Wiring loads over 5 Amps using external relays.

BWI Eagle AIR-EAGLE XLT 441-8000-R1NC-DC Specifications

General IconGeneral
BrandBWI Eagle
ModelAIR-EAGLE XLT 441-8000-R1NC-DC
CategoryReceiver
LanguageEnglish