Installation and operating manual EN
Medo XB / 2016-08 / © BWT Wassertechnik GmbH/Printed in Germany
Medo
®
XB
Metering pumps
Types: XB 4, XB5
Changes reserved!

Questions and Answers

  • J
    Jason LeeJul 25, 2025
    What to do if the red LED is on and BWT Medo XB4 Water Pump stops?
    • J
      Jessica GuzmanJul 26, 2025
      If the red LED indicator lights up and the BWT Water Pump stops, it could be due to a low liquid level in the storage tank. Refill the storage tank. Alternatively, if an external cable is connected while the multifunctional switch is not set to "Extern," either switch to "Extern" or disconnect the external cable.
  • J
    Jermaine CastroJul 31, 2025
    Why BWT Medo XB4 Water Pump does not prime after bleeding?
    • A
      Allison RobertsonJul 31, 2025
      If the BWT Water Pump doesn't prime despite full stroke motion and bleeding, it might be due to minor or major crystalline deposits on the ball seat because the valves are drying out. * For minor deposits, flush out the liquid end thoroughly by removing the suction hose from the storage tank. * For major deposits, dismantle and clean the valves.
  • K
    Katie PetersonAug 6, 2025
    What to do if yellow LED lights up on BWT Medo XB4?
    • T
      Tiffany SchultzAug 7, 2025
      If the yellow LED indicator lights up on the BWT Water Pump, it means the liquid level in the storage tank has reached the "liquid level low 1st stage". To resolve this, fill the storage tank.
  • K
    Kevin SharpAug 13, 2025
    What to do if fluid is escaping from the backplate of BWT Medo XB4?
    • C
      Clayton HuntAug 13, 2025
      If fluid is escaping from the backplate of your BWT Water Pump, it could be due to: * Loose screws in the dosing head: Tighten the screws crosswise. * A loose metering diaphragm: Replace the diaphragm.
  • E
    Emily HawkinsAug 18, 2025
    How to fix BWT Medo XB4 Water Pump when green LED is off?
    • S
      Stephanie KingAug 18, 2025
      If the green LED display (operating display) does not light up on your BWT Water Pump, the wrong or no mains voltage is connected. Connect the pump correctly to the specified mains voltage as indicated on the nameplate.

Summary

Identity Code

Safety chapter

Safety Information Definitions

Defines signal words (WARNING, CAUTION) and warning signs.

Correct and Proper Use Guidelines

Outlines rules for proper pump usage and prohibited applications.

Specific Safety Notes and Warnings

Details critical warnings for personal, electrical, fire, and chemical safety.

Emergency Procedures

Provides instructions for actions in emergency situations.

Overview of Equipment and Control Elements

Control Panel Components

Details individual control elements like switches, knobs, and indicators.

Functional Description

Electrical Installation

Supply Power Connection

Guides on connecting the pump to the mains power supply and parallel connections.

External Control and Level Switch Terminals

Explains the function and wiring of the external control and level switch terminals.

Operation

Troubleshooting

Troubleshooting: Faults Without Alert

Lists faults that occur without an indicator light and their solutions.

Troubleshooting: Fault Alerts

Describes causes and remedies for red LED fault indicators and pump stops.

Troubleshooting: Warning Alerts

Explains causes and remedies for yellow LED warning indicators.

Technical Data

BWT Medo XB4 Series Specifications

General IconGeneral
Insulation ClassF
Frequency50 Hz
Housing MaterialCast iron
ApplicationWater supply, irrigation
Impeller MaterialStainless Steel
Suction Lift8 m
Voltage230/400 V
Inlet/Outlet Size1 inch