BEYOND ResPlus B-30P Bi-Level PAP
User Manual
Please read this manual carefully before using this product

Questions and Answers

Summary

Introduction

Intended Use

Defines the device's purpose for adult patients with respiratory insufficiency or OSA.

Warnings

Alerts users to potential risks and hazards associated with device operation.

Cautions

Highlights actions that might damage the device or injure the user.

Contraindications

Lists conditions where the device should not be used or used with caution.

Model

Package Contents

Device Components

Device Symbols

Device Operation

First Use

Step-by-step guide for initial setup and operation of the device.

Daily Use

Details regular usage procedures for the device after initial setup.

Humidifier

Humidifier Composition

Details the components that make up the humidifier unit.

Humidifier Connection & Separation with the Host Unit

Instructions for attaching and detaching the humidifier from the main unit.

Adding water into the water tank

Guide on how to properly fill the humidifier's water tank.

Using the SpO2 Kit

Parameter settings

Main Interface Screens

Describes the primary display screens of the device's user interface.

PFCurve interface

Details the interface for monitoring and adjusting pressure and flow curves.

Parameter Setting Interface

Guide to accessing and modifying various device settings and parameters.

System setting interface

Instructions for configuring system-level settings like time, date, and language.

Information setting interface

Explains how to view device usage data and performance metrics.

Alarm Interface

Details how to set up and manage device alarms for various conditions.

Prompt

Cleaning, Disinfection and Maintenances

Timing between Cleanings

Recommends a schedule for cleaning and replacing device components.

Cleaning

Outlines the steps for cleaning the device and its accessories.

Cleaning the host and tubing

Specific instructions for cleaning the main unit and the breathing tube.

Cleaning the water tank

Steps for cleaning the humidifier's water tank.

Clean and Replace the air filter

Procedures for cleaning and replacing the device's air filter.

Disinfection

Guidelines for disinfecting device components, especially for clinic use.

Transferring to another patient

Procedures for preparing the device when switching between patients.

Troubleshooting

Specifications

Traveling with the Device

Service

Technical Support

Disposal

Warranty

EMC Requirements

Byond ResPlus B-30P Bi-Level PAP Specifications

General IconGeneral
Data StorageSD Card
Operating Voltage100-240 V AC, 50/60 Hz
Device TypeBi-Level PAP
IPAP Range4-30 cmH2O
EPAP Range4-25 cmH2O
Pressure Range4-30 cmH2O
Rise Time1-6 settings
AlarmsPower failure, Low pressure
DisplayLCD screen
Power SupplyExternal AC adapter
Humidifier CompatibilityIntegrated heated humidifier
HumidifierIntegrated heated humidifier
ModelByond ResPlus B-30P