EasyManua.ls Logo

C.A. Technologies Cougar - Compressed Air Requirements

C.A. Technologies Cougar
4 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Revised 3/20/14
5
4
3
2
1
20 40 60
1500 PSI FLUID (107 PSI AIR)
1000 PSI FLUID (72 PSI AIR)
350 PSI FLUID (25 PSI AIR)
SCFM
13 26 39
C14 AAA Pump Air Consumption
Gun Air Consumption
CougarCougar
CougarCougar
Cougar
5
4
3
2
1
10 20 30
SCFM
*
Gun Regulator Pressure - PSI
*Max pressure for HVLP
Pump Speed - Cycles per minute
Pump Output - Ounces per minute
Compressed Air Requirements
Minimum compressor size will vary with the application. Air requirements for the gun and pump must be added together for total air
requirements.
Example: Gun Regulator Setting 25 psi, scfm = 3.5
Pump fluid pressure is 1000 psi and cycle rate is 30, scfm = 1.75
Minimum compressor requirement: 3.5+1.75 = 5.25 scfm
Fluid Tip Flow Rate Chart (Fluid oz/min.)
Tip Size
Light
Materials
Heavy
Materials
Light
Materials
Heavy
Materials
Light
Materials
Heavy
Materials
Light
Materials
Heavy
Materials
0.007 3 --- 4 --- 5 --- 6 ---
0.009 5 --- 8 --- 9 --- 11 ---
0.011 8 --- 11 --- 13 --- 16 ---
0.013 10 --- 14 --- 17 --- 21 ---
0.015 13 --- 18 --- 22 --- 27 ---
0.0171713241829223527
0.0192116302336274433
0.0212721382945355643
Note: Values are approximate and will vary depending on actual material viscosity.
Pressure (psig)
350 700 1000 1500