DIGITAL CONTROLLER WITH TIMER+STEAM INSTRUCTION MANUAL
ON / OFF
SR-D961
*
*
No、hi、lo、dFh、dFl
No、hi、lo、dFh、dFl
A2Y
A1Y
A2F
A1F
Td2
Td1
Act
f
I
l
LOL
TYP
ON
SPO
PVO
Hys
Ct
P
A1
A2
CH
CL
VER
LOL~ HIL
LOL~ HIL
0~100
0~50%FS
-
99~50%FS
0~100
1、2、3
K . J
0~SV
0~100
H/C
0、5、10、30
0~100
0~500
0~500
0~A2
0~A1
℃
℃
℃
℃
℃
℃
℃
℃
℃
%
type
CT=0
H: C:
10
20
0
2
0
0
1
K
0
400
2
H
0
0
NO
1
1
470
90
H
L
I
A1F
A2F
PANEL DESCRIPTION
UP / DOWN KEY
OUTPUT
INDICATOR
ON / OFF BUTTON KEY: Power on/off button key. It is also used to
enter each parameter level for setting.
UP KEY: Is used to increment set value.
Whether the power had directly applied or by pressing the ON/OFF power button, the
screen will display the set temperature value (flashing) first, then to be followed by the
current temperature value.
Regardless of what parameter level you are in, if left idle within 5 secs, the display
will automatically return to its original operation mode.
PARAMETER DESCRIPTION LIST AND SETTING:
CODE DESCRIPTION
SETTING RANGE UNIT
DEFAULT
VALUE
REMARKS
LEVEL 1
LEVEL 2
LEVEL 3
ALARM1 SET VALUE
ALARM2 SET VALUE
IF SET NO, NO DISPLAY
IF SET NO, NO DISPLAY
PROPORTIONAL BAND
BECOMES ON/OFF CONTROL
IF P=0
CYCLE TIME
PARAMETER NOT AVAILABLE IF P=0
AVAILABLE IF P=0
HYSTERESIS
PV OFFSET
SV OFFSET
ON/OFF SETTING MODE
REFER TO NOTE (1) -
ON/OFF MODE SETTING DESC.
INPUT SELECTION TYPE
LOWEST TEMP. SETTING LIMIT
HIGHEST TEMP. SETTING LIMIT
FILTER SETTING
CONTROL ACTION SETTING
HEATING
COOLING
SV LOOP DISPLAY SETTING
ALARM DELAY TIME SETTING
SEC.
SEC.
ALARM1 MODE SETTING
ALARM2 MODE SETTING
REFER TO NOTE (3) -
ALARM OUTPUT TYPES
REFER TO NOTE (3) -
ALARM OUTPUT TYPES
ALARM1 HYSTERESIS SETTING
SEC.
ALARM2 HYSTERESIS SETTING
4-20mA OUTPUT HIGHEST SETTING
4-20mA OUTPUT LOWEST SETTING
VERSION
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS)
ONLY APPEARS WHEN
CT=0
ONLY APPEARS WHEN
2017 NO. 1
RELAY = 10 SEC
SSR = 2 SEC
SCR = 0 SEC
SV~400
、4
、
5
TON
TIME-ON SELECTION
TeD
TIME-END SELECTION
、 OFF
A. FOR TEMPERATURE CONTROL PARAMETER
TEMPERATURE
KEY SETTING
TIMER KEY
SETTING
DOWN KEY: Is used to decrement set value.
“OFF”
NOTE (1): ON/OFF MODE SETTING DESCRIPTION:
CODE MODE DESCRIPTION
SCREEN DISPLAY
“OFF”
ALL OFF
NO DISPLAY
OUTPUT STOP, ALARM OFF
OUTPUT STOP, ALARM ON
OUTPUT STOP, ALARM OFF
4
5
POWER ON:
OUTPUT STOP, ALARM OFF
SCREEN DISPLAYS
“OFF” WHEN
POWER ON
POWER ON:
OUTPUT STOP, ALARM OFF
DECIMAL POINT
LIT ON
NOTE (3): ALARM OUTPUT TYPES ILLUSTRATION:
(A1F AS EXAMPLE)
DFL
DFH
lo
hi
No
CODE
DESCRIPTION TYPE
ILLUSTRATION
NO ALARM
NONE
ABSOLUTE VALUE
UPPER LIMIT
ABSOLUTE VALUE
LOWER LIMIT
DEVIATION
UPPER LIMIT
DEVIATION
LOWER LIMIT
A1
A1 ON
SV
A1
A1 ON
SV
A1 ON
A1
It refers to the difference between the display temperature
value and the setpoint value.
TON
NOTE (2): Setting the value range for
For instance:
SV = 100
TON = 1
It indicates that once the temperature reaches 99 degrees
celcius, the controller timer will start automatically.
OFF BUTTON KEY: Is used to stop/halt output. Screen display “OFF”,
flashing together with the current temperature value alternately.
ON BUTTON KEY: Output ON. Display SV temperature (flashing)
first, then in a few seconds it will display the current temperature after.
IF = on, OUTPUT
TURNS OFF AUTOMATICALLY.
- 1 -
TeD
NO
REFER TO NOTE (2) -
SETTING TON VALUE
B. EXPLANATORY NOTE:
LED ON: OUTPUT ON
LED OFF: OUTPUT OFF
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS TO ENTER EACH PARAMETER LEVEL)
、60
1~300
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS)
DB
-
-50~50 0 SETTING NOT AVAILABLE
、
on OFF
-
99~50%FS
OFF
OFF