105
.............................................................................................................................................................................................................................................
S2
MU3804 RED/GREEN STEREO BARGRAPH DIL SWITCHES
SW1 +6dBu at the scale "0" position (PPM only):-
1 = LEFT BAR } UP = ON = +6dBu at scale "0".
2 = RIGHT BAR } DOWN = OFF = +8dBu at scale "0".
SW2 PPM/VU characteristics, LEFT BAR :-
LEFT = PPM.
RIGHT = VU.
SW3 PPM/VU characteristics, LEFT BAR :-
LEFT = VU.
RIGHT = PPM.
SW4 PPM/VU characteristics :-
1 = LEFT BAR } UP = ON = VU.
2 = RIGHT BAR } DOWN = OFF = PPM.
SW5 PPM/VU characteristics, RIGHT BAR :-
LEFT = VU.
RIGHT = PPM.
SW6 PPM/VU characteristics, RIGHT BAR :-
LEFT = VU.
RIGHT = PPM.
N.B. All the above switches should be in the same position (i.e. VU or PPM) to achieve proper
performance (It is remotely possible to have different characteristics on LEFT and RIGHT BARS when
used for other than stereo metering.)