CX-ED2079-1
‘ANSI’ Electric Strike
Installation Instructions
1. Description
Camden CX-ED2079-1 low prole grade 2 ANSI strike for
cylindrical locksets offers the very best strike quality and
performance, with three stainless steel faceplates provided.
The ‘ANSI’ strike design delivers unparalleled application
exibility, with eld selectable voltage, fail safe/fail secure
operation and mechanical adjustment of the strike body.
1- 4 PIN power connector
1- ESP1B faceplate
4- Wire nuts
5- M5 x 12mm screws
2- #10 x 1 1/4” wood
screws
2- #10-32 x 1/2” screws
2- Mounting brackets
2- Spacers
1- Varistor
1- Trim Plate
This Package Includes:
Page 1 of 3
2. Specifications
Voltage
12/24V AC/DC
Current Draw
300mA@12V DC
150mA@24V DC
Static Strength
1,000 Lbs.
Dynamic Strength
50 Ft-Lbs.
Endurance
700,000 Cycles (Factory Tested)
250,000 Cycles (UL Verified)
Mode
Field Selectable
Fail Safe/Fail Secure
Mech. Adjustment
Strike Body/Faceplate
Operation
AC-Buzz
DC-Silent
Duty
Continuous
Dimensions (Body)
3 3/8” H x 1 7/8” W x 1 7/32” D
(86mm x 47mm x 31mm)
3. Dimensions
(32mm)
1 1/4”
(3mm)
1/8”
(12mm)
(86mm)
3 3/8”
1/2”
(32mm)
(16mm)
1 1/4”
(42mm)
1 5/8”
(19mm)
3/4”
5/8”
(104mm)
4 1/8”
(123mm)
4 7/8”
(47mm)
1 7/8”
(31mm)
1 7/32”
(31mm)
1 7/32”
(31mm)
1 7/32”
UL 1034
UL 294
Question and Answer IconNeed help?

Do you have a question about the CAMDEN CX-ED2079-1 and is the answer not in the manual?

CAMDEN CX-ED2079-1 Specifications

General IconGeneral
BrandCAMDEN
ModelCX-ED2079-1
CategoryDoor locks
Operating Voltage12/24 VDC
HandingNon-handed
Strike Plate IncludedYes
Mounting Hardware IncludedYes
Door TypeWood, Metal
Backset2-3/4 inches
Door Thickness1-3/4 inches
Solenoid TypeFail-Safe

Summary

Product Description and Specifications

Product Description

Low profile grade 2 ANSI electric strike for cylindrical locksets, offering flexibility with field selectable voltage, fail safe/fail secure operation.

Electrical Specifications

Details voltage, current draw, static strength, dynamic strength, endurance, mode, mechanical adjustment, operation, duty, and body dimensions.

Product Dimensions

Provides detailed measurements and diagrams for the electric strike unit and its components.

Installation Guide

Step-by-Step Installation

Instructions for preparing the door jamb, installing mounting brackets, using spacers, connecting wires, and securing the strike.

Connections and Operation

Electrical Connections

Wiring diagram and notes for 12VDC and 24VDC power, including varistor connection and power source recommendations.

Fail-Safe/Fail-Secure Operation

Guidance on modifying the electric strike's fail-safe to fail-secure or vice versa by adjusting the set plate.

Faceplate Options

Illustrations and dimensions for included and additional faceplates suitable for different door types.