Output 12 Vdc for external powering accessories. The maximum absorption of 1 A corresponds to the
sum of all the terminals 1 (+12V).
Contact N.O. opening A side (interior side).
Contact N.O. opening B side (outer side).
Contact N.O. aperture priority, connect to devices accessible only by authorized personnel with keys or
codes.
Contact N.O. closing priority, connect to devices accessible only by authorized personnel with keys or
codes.
Safety contact N.C. on doorway side A (interior side). When the door is closing, the opening of the
contact causes the reversal of the movement.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 8A.
Safety contact N.C. on doorway side B (outer side). When the door is closing, the opening of the contact
causes the reversal of the movement.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 8A.
Opening safety contact N.C. side A (left side). When the door is opening, the opening of the contact
causes the slowdown of the door in the last 500 mm (the safety function of the terminal 6 can be
changed using the advanced settings menu).
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 6A.
Opening safety contact N.C. side B (right side). When the door is opening, the opening of the contact
causes the slowdown of the door in the last 500 mm (the safety function of the terminal 6 can be
changed using the advanced settings menu).
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 6A.
Output test (+12 V). Connect the safety devices with test (in accordance with EN 16005), as indicated in
the following chapters.
Note: in case of devices without test, connect the N.C. contact to terminals 41 - 8A or 41 - 8B, or 41 - 6A,
or 41 - 6B.
Input terminal provided for general use.
Using the ADV > STG1 menu you can choose a specific function to the G1 terminal.
Input terminal provided for general use.
Output terminal (12 Vdc, 20mA max) provided for general use.
Using the ADV > STG2 menu you can choose a specific function to the G2 terminal.
Contact N.C. limit-switch of the locking device.
Reset contact N.O. Closure and release the contact starts the learning operation of the door.
Bus connection to the function selector.
Standard admission for memory cards Micro SD. Allows saving the door settings and loading the firmware
updates.
Current input for the opening sensor for emergency exit side A, internal view of automation (remove the
jumper and the resistor of the terminals).
Contact N.C. of emergency opening. The opening of the contact causes the door to open (connect the
emergency opening device and remove the bridge 1 – EO).
Scroll the menu and increase of selected values.
Scroll the menu and reduction of selected values.
Button to select the menu and save the selected data.