4. SIZING FRAME SYSTEM FOR SLIDING DOORS
The correct sizing of an automatic sliding door depends on the size of the compartment wall and the present encumbrance.
The following tables provide the installation measurements refer to the codes list (considering perimeter profiles and
overlaps average), are also indicated the applied formulas to obtain the installation measurements based on the actual
dimensions of the wall and frame systems.
To facilitate the calculations and the choice for the ordination of automatic sliding doors, CAME S.p.A. has developed the
CAME DoorConfigurator computer program.
4.1 SIZING FRAME SYSTEM FOR 2 SLIDING DOORS
Ld = La + 2Lm + 20 automation length
La = 2Lm + Loc – 2Loo width of the doorway
Lm = (La – Loc + 2Loo) / 2 leaf width
Loo = overlapping open side door (depending on the type of used frame system)
Loc = overlapping closes side door (depending on the type of used frame system)
A = Ld/2 – La/2 – 350 = positioning of the transmission unit (maximum size)
B = Ld/2 – La/2 – 340 = positioning of the drive unit (maximum size)
C = Ld/2 – 70 = positioning of the locking device
Length of belt = (Ld – A – B – 65) x 2 (minimum length)
(N.B. Values shown are calculated considering Loo = 50 mm e Loc = 0 mm)