13
TROUBLESHOOTING
Fault
Cause
Solution
Light on, but
fan does not
work.
The fan blade is
jammed.
Switch off the unit. Repair to carried out
by qualified service personnel only.
The motor is damaged.
Both light and
fan do not
work.
LED light burn.
Replace the light with correct rating.
BULB REPLACEMENT
Important :
The bulb must be replaced by the manufacturer, its
service agent or similarly qualified persons.
Always switch off the electricity supply before
carrying out any operations on the appliance. When
handling bulb, make sure it is completely cool down
before any direct contact to hands.
When handling globes hold with a cl oth or gloves to
ensure perspiration does not come in contact with
the globe as this can reduce the life of the globe.
Changing the light:
*Before changing the lights, make sure that the appliance is plugged off.
*Use the screw driver loosen the ST4*8MM self tapping screw (2pcs) from the lighting
panel, take out the lighting fixture. Open the terminal box that connected with the wire,
disconnect the wire connector and replace the lamp.
ILCOS D code for this lamp is: DBS-2/65-H-120/33
LED modules rectangle lamp
Max wattage: 1*2 W
Voltage range: AC 110-240V
Dimensions: