Capacity of Texas, Inc.
72
168
{18}
Battery 1 Voltage - Data Valid
but Below Normal
Operational Range -
Moderately Severe Level.
ECM supply voltage is below
the minimum system voltage
level.
Engine may stop running or be
difficult to start.
168
{16}
Battery 1 Voltage - Data Valid
but Above Normal Operational
Range - Moderately Severe
Level. ECM supply voltage is
above the maximum system
voltage level.
Possible electrical damage to
all electrical components.
157
{0}
Injector Metering Rail 1
Pressure - Data Valid But
Above Normal Operating
Range - Most Severe Level.
Fuel pressure signal indicates
that fuel pressure has exceeded
the maximum limit for the
given engine rating.
The engine may be derated.
157
{3}
Injector Metering Rail Number
1 Pressure Sensor Circuit -
Voltage Above Normal or
Shorted to High Source. High
signal voltage detected at rail
fuel pressure sensor circuit.
Power and or speed derate.
157
{4}
Injector Metering Rail Number
1 Pressure Sensor Circuit -
Voltage Below Normal or
Shorted to Low Source. Low
signal voltage detected at the
rail fuel pressure sensor
circuit.
Power and or speed derate.
98
{17}
Engine Oil Level - Data Valid
But Below Normal
Operational Range - Least
Severe Level. Low oil level
has been detected by the oil
level sensor.
The engine may derate.
Possible low oil pressure.
Possible severe engine
damage.
Table 4-3 CM2150 System Fault Codes (Cont.)