    Why do I get noise and artifacts on the ECG signal with my Cardioline Clickholter Medical Equipment?
    • E
      erayAug 12, 2025
      Noise and artifacts on the ECG signal from your Cardioline medical equipment often indicate that the electrode-skin contact is not optimal. To resolve this: 1. Ensure all electrodes are properly attached to the patient and to the cable. 2. Make sure the electrodes haven't expired.
  • C
    Colton WilkersonAug 16, 2025
    What to do if my Cardioline Clickholter Medical Equipment display does not switch on?
    • J
      joshuabrownAug 16, 2025
      If the display of your Cardioline medical equipment doesn't switch on, here are a few things to check: 1. Make sure the batteries are installed correctly, paying attention to the polarity. 2. Replace the batteries if the battery voltage is too low. 3. If the problem persists after checking the batteries, hand the unit to your dealer or directly to Cardioline.
  • S
    Steven GoodwinAug 19, 2025
    What to do if my Cardioline Clickholter Medical Equipment is not detected when connected to the PC and the display does not switch on?
    • D
      David ScottAug 19, 2025
      If your Cardioline medical equipment is not detected when connected to your PC and the display remains off, the device might be off. Press the central button to switch the device on.
  • D
    Dean PayneAug 25, 2025
    What to do if my Cardioline Medical Equipment is detected by the PC but the memory is not accessible?
    • A
      anthonybowmanAug 25, 2025
      If your Cardioline device is detected by the PC but the memory isn't accessible: 1. Try formatting the PC memory (select filesystem FAT32). 2. If that doesn't work, hand the unit to your dealer or directly to Cardioline.
  • A
    Alison BrownAug 27, 2025
    What to do if the green LED of battery status blinks and the display does not switch on in my Cardioline Clickholter?
    • K
      Kenneth GarnerAug 27, 2025
      If the green LED of the battery status is blinking and the display doesn't switch on for your Cardioline medical equipment, the inserted battery might not be sufficiently charged. Replace it with a new alkaline or lithium battery.
  • C
    cjonesAug 31, 2025
    What to do if my Cardioline Clickholter Medical Equipment display switches on but no screen is displayed?
    • S
      Stephanie TaylorAug 31, 2025
      If the display switches on but no screen is displayed on your Cardioline medical equipment, the inserted battery might not be sufficiently charged. Replace it with a new alkaline or lithium battery.
  • B
    Brittany MooreSep 4, 2025
    What to do if my Cardioline Clickholter displays the message “SD Card not recognized. Connect the device to PC. See user manual for details”?
    • P
      Peter HickmanSep 4, 2025
      If your Cardioline device displays the message “SD Card not recognized”, it means the device is unable to recognize the SD card. Try connecting the device to a computer using the USB cable. If the SD card remains inaccessible, format it using FAT32 according to Windows instructions. Disconnect the device from the PC and switch it on. If the problem continues, contact Cardioline service.
  • S
    Susan OwensSep 8, 2025
    Why my Cardioline Clickholter does not respond to HIRES programming (webuploader)?
    • J
      Jessica WhiteheadSep 8, 2025
      The Cardioline device may not respond to HIRES programming because the Hires configuration isn't supported and is converted to 7dd/250Hz. Avoid using webuploader if you intend to capture a high-resolution trace (500 or 1000 Hz).

Summary

SAFETY INFORMATION

General Safety Information

Essential safety guidelines, warnings, and precautions for device operation.

Recommendations for the patient during the test

Instructions and warnings for patients undergoing ECG tests.

PREPARATION FOR USE

Switching On and Commissioning

Steps for powering on, initial setup, and configuration of the recorder.

EXECUTION OF THE EXAMINATION

General Procedure and Patient Preparation

Step-by-step guide to performing a Holter test and preparing the patient.

Patient Cable Connections

Detailed instructions for using 5, 7, and 10-wire patient cables.

Recording Preparation and Start

Guide to preparing, starting, and managing recording sessions.

Ending and Data Transfer

Procedures for ending recordings and transferring data to a PC.

RECORDER SETTINGS

MAINTENANCE AND TROUBLESHOOTING

Troubleshooting Common Issues

A table listing problems, causes, and solutions for device malfunctions.

Cardioline Clickholter Specifications

General IconGeneral
Sampling Rate128 Hz
Pacemaker DetectionYes
Data TransferUSB
Dimensions90 x 60 x 20 mm
Weight120 g
Channels3
Resolution16 bit
CompatibilityWindows