Description
DPC01 and PPC01 are 3-phase mains monitoring
relays.
They operate on 3P and 3P+N systems,
monitoring phase loss and phase sequence,
overvoltage and undervoltage, voltage asymmetry
and tolerance.
Power supply provided by the monitored mains.
Two independent delay functions, up to 30 s, for
over / under voltage and asymmetry / tolerance
alarms.
Benefits
Wide voltages and frequency ranges. Working in
systems from 100 to 690 VAC and 50 to 400 Hz.
Adjustable voltage levels, asymmetry, tolerance
and time delay. To allow a correct response to real
alarm conditions.
Output and status LED indication. For quick
troubleshooting.
Two mounting versions. Available for DIN-rail
(DPC01) and Plug-in (PPC01) mounting.
Adjustable power ON delay. To avoid nuisance
tripping at start-up.
Ultra-high harmonic immunity. For very noisy
environments.
Main features
Monitoring 3-phase mains with 3 wires (3P) or 4 wires (3P+N).
Detection of the correct phase sequence, phase loss, asymmetry and tolerance.
Front dial adjustable overvoltage, undervoltage, asymmetry and tolerance setpoints.
Time delay.
Two changeover relay outputs.
14/10/2022 DPC01_PPC01_DS_ENG Carlo Gavazzi Controls S.p.A.
1
DPC01, PPC01
True RMS 3-Phase voltage monitoring relay
Question and Answer IconNeed help?

Do you have a question about the CARLO GAVAZZI DPC01 and is the answer not in the manual?

CARLO GAVAZZI DPC01 Specifications

General IconGeneral
MountingDIN rail
Supply voltage24 – 240 VAC/DC
OutputSPDT
Contact FormSPDT
Coil Voltage24 V AC/DC
Mechanical Life30 million operations
Electrical Life100, 000 operations
Operating Temperature-20 to 60 °C

Summary

Description and Features

Product Description

Overview of DPC01 and PPC01 3-phase mains monitoring relays and their functions.

Key Benefits

Highlights advantages like wide voltage ranges, adjustable settings, and immunity.

Main Features

Lists primary functionalities including phase monitoring, asymmetry, and time delays.

Order Code and Structure

Order Code Selection

Table detailing part numbers based on mounting, frequency, and power supply.

Device Structure Overview

Illustrates the components and terminals of DPC01 and PPC01 units.

Technical Features

Frequency Range

Specifies the frequency ranges for sinusoidal waveforms supported by the device.

Power ON Delay

Defines the delay before the relay becomes active after power-up.

Inputs

Input Terminals and Variables

Details input terminals and measured variables like phase sequence and asymmetry.

Nominal Voltage Ranges

Lists the nominal operating voltage ranges and specific voltages for different models.

Outputs, Insulation, and General Specifications

Output Specifications

Details terminals, type, logic, contact rating, and lifetime of outputs.

Insulation Specifications

Details basic insulation values for input and output terminals.

General Device Specifications

Includes material, colour, dimensions, weight, and terminal type.

Environmental and Resistance Specifications

Environmental Conditions

Specifies operating/storage temp, humidity, protection, altitude, salinity, UV.

Vibration/Shock Test Results

Lists test conditions and levels for unpacked and packed devices.

Conformity and Operation

Certifications and Directives

Covers CE, UKCA marking, directives, standards, and approvals.

DIP Switch Configuration

Explains DIP switch settings for typology and function.

DIP Switch Settings Diagrams

DIP Switch Settings for M44, M11, M23

Illustrates DIP switch configurations for M44, M11, and M23 models.

DIP Switch Settings for M48, M49, M69

Illustrates DIP switch configurations for M48, M49, and M69 models.

Device Configuration Details

Voltage Asymmetry Calculation

Defines how phase-phase and phase-neutral asymmetry is calculated.

Voltage Tolerance Calculation

Defines how phase-phase and phase-neutral voltage tolerance is calculated.

Adjustment Dial Functions

Overvoltage/Asymmetry Adjustment

Describes the function and resolution of the overvoltage/asymmetry dial.

Undervoltage/Tolerance Adjustment

Describes the function and resolution of the undervoltage/tolerance dial.

Delay Setting Dials

Details the function and resolution for setting alarm ON delays.

Alarm Conditions

Phase Loss and Sequence Alarms

Details input variables, reaction time, hysteresis, and delays for phase loss/sequence.

Voltage/Asymmetry/Tolerance Alarms

Details input variables, ranges, repeatability, hysteresis, and delays.

Information LEDs and Operating Diagram

Information LEDs

Explains the status and description of Green, Red, and Yellow LEDs.

Over/Undervoltage Operating Diagram

Illustrates the relay behavior for over and undervoltage monitoring.

Phase Loss/Sequence Operating Diagram

Total Phase Loss/Sequence Timing

Diagram showing relay and LED status during phase loss or sequence faults.

Asymmetry/Tolerance Operating Diagram

Asymmetry and Tolerance Timing

Illustrates relay and LED behavior during asymmetry and tolerance monitoring.

Connection Diagrams and References

Wiring Connection Diagrams

Provides wiring diagrams for DPC01 and PPC01, including terminal layouts.

Further Reading and Copyright

Links to installation manuals and copyright information.