CONTROLS MANUAL
Original document
Touch Pilot Control
19PV 550-1600
Question and Answer IconNeed help?

Do you have a question about the Carrier 19PV 1600 and is the answer not in the manual?

Carrier 19PV 1600 Specifications

General IconGeneral
BrandCarrier
Model19PV 1600
CategoryChiller
LanguageEnglish

Summary

General Description

Safety Considerations

Safety Guidelines

Outlines general safety practices for installation, start-up, and servicing of the equipment.

Safety Precautions

Details precautions for working with electrical components, including risks of electrocution and burns.

How to Use Touch Pilot Control

How to Use Touch Pilot Control

Menu Structure

Provides a visual overview of the Touch Pilot menu structure, including Main menu, Configuration menu, and Alarms menu.

Setting Up Touch Pilot Control

Schedule Setting

Explains how to set up time schedules for unit occupancy and setpoint selection using OCCPC01S and OCCPC02S.

Unit Start/Stop

Explains how to start and stop the unit using the Start/Stop button and select operating modes (Local, Network, Remote, Master).

Setting Up Touch Pilot Control

Setting Up Touch Pilot Control

Configuration Menu

Details how to access and use the Configuration menu for modifying parameters like pump, schedule, and user settings.

Setting Up Touch Pilot Control

Web Connection

Covers accessing the Touch Pilot control via a web browser, including connection requirements and IP address.

Detailed Menu Structure

General Parameters Menu – GENUNIT

Lists parameters within the General Parameters menu, covering operating mode, setpoints, capacity, and emergency stop.

Configuration Menu (CONFIG1)

Details the items within the Configuration menu, including general, pump, user, reset, schedule, and holiday settings.

Detailed Menu Structure

Detailed Menu Structure

Setpoint Table Menu – SETPOINT

Defines setpoints for cooling, heating, ice storage, ramp loading, and demand limits, including default values and ranges.

General Configuration Menu – GEN_CONF

Lists parameters within General Configuration, covering circuit priority, ramp loading, unit delays, demand limit types, and night mode.

Standard Control Operations and Options

Start/Stop Control

Explains how the unit's start/stop state is determined by operating type, overrides, contacts, and alarms.

Standard Control Operations and Options

Reset Functionality

Explains how reset modifies the control point to adjust machine capacity based on demand sources like OAT or Delta T.

Active Setpoint Selection

Details how to select active setpoints in Cooling and Heating modes, and the factors influencing selection.

Demand Limit Functionality

Covers the demand limit functionality to limit power consumption using contacts, network settings, or night capacity.

Standard Control Operations and Options

Standard Control Operations and Options

Dry Cooler Free Cooling (Option 313)

Explains the free cooling option using a dry cooler to directly exchange heat with outside air for cooling.

Diagnostics

Control Diagnostics

Explains the fault tracing aid functions of the Touch Pilot system and how to view unit status and alarms.

Resetting Alarms

Details how to reset alarms manually through the interface or automatically by the control.

Diagnostics

Alarms Description - Thermistor & Pressure Failures

Details alarms, possible causes, actions, and reset types for thermistor and pressure transducer failures.

Alarms Description - Communication & Protection Failures

Details alarms, possible causes, actions, and reset types for communication and unit protection failures.

Alarms Description - Compressor & Module Failures

Details alarms, possible causes, actions, and reset types for compressor and module failures.