EasyManua.ls Logo

Carrier 30HR090 - Page 2

Carrier 30HR090
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EACH END
POWER INLET
ON THIS
P
100,110,120,140,160 ONLY
G
ONE FOR 070,080,090
(FACTORY-SUPPLIED,
FIELD-INSTALLED)
N-1
M
FAR END
A-A
C
D
BOTH
MANIFOLDS
MANIFOLD
(SEE (INLET)
NOTE)
5
81
X
LEFT SIDE VIEW
10
INLET END - 2 r DIAM
:7
2
OUTLET END- 4" DIAM
30HRI60, BOTH CONDENSERS (WITH REMOVABLE NOZZLES, SCH 40 STEEL PIPES)
op
(D
.L-BOTH
1
SIDES '
BOTH
SIDES
MANIFOLD COUPLIN
I
(SEE NOTE 0)
-E MTG HOLES
E g_MTG HOLES
(INCLUDES COOLER OVERHANG ON 140,160)
FRONT VIEW
MANIFOLD
OUTLET
(ACCESSORY)
(SEE
NOTE)
710N 30HRI60
R
BOTH SIDES
30HR
-c.
MT
G
HOLES
A
..
2'-9
-
"
1
B
8
-+ NOTE: Accessory mani-
fold inlet and outlet
connections:
070-090 units -- 4",
150 lb ASA flat-face
flange.
100-140 units — 5",
150 lb ASA flat-face
flange.
FRONT VIEW
(CIRCUIT NO. 2)
W ODM DISCH LINE (CIRCUIT 2)
V ODM DISCH LINE (CIRCUIT I )
(CIRCUIT NO. I) TO THERMOSTATIC
EXPANSION
VALVES
FILTER-DRIER
H
FILTER-DRIER
LIQUID
CONN.
LIQUID CONN.
VIEW A-A (30HS070-120)
L
(CIRCUIT NO.1)
(CIRCUIT
NO.2)
TO
THERMOSTATIC
EXPANSION
VALVES
FILTER-DRIER
LIQUID CONN.
FILTER-DRIER
LIQUID CONN.
VIEW A-A (30HSI40,160)
30HS
DIMENSIONS (ft-in.)* (font "
d)
"
DIMENSIONS (ft-in.)*
MUFFLER
LEFT SIDE VIEW
DIM.
30HR,HS
070,080,090
100,110,120
140
I
160
A
8-6
9- 4
10-11-1/2
B
2-11-7/8
2-11-7/8
2-11-7/8
C
(HR)
6- 9-5/8
7- 0-3/4
7- 0-1/4
C (HS)
4- 9-3/4
5- 0-1/8 5- 0-3/4
D (HR)
6-2
6- 4-3/4
6- 4-1/2
D
(HS)
4- 2-3/4 4- 4-1/8
4- 4
E
4-
1-1/2
4- 6-1/2 4- 6-1/2
F
1- 8-1/4
2- 4
0- 7-7/8
G
6- 0-3/4
6- 0-3/4
7-10-5/16
H (HS)
7-10-5/8
8- 4
8- 0-3/8
J (HS)
3- 3-1/2
3- 3-1/4
2-11-9/16
K (HS)
4- 6-5/8
3-10
3-10
L (HS)
5- 0-1/8 4- 3-1/2
4- 3-1/2
M (Diam)
1-0
1- 3-1/2
1-
5-1/2
N
6-10-3/4
6- 8
9- 2-1/2
P
5-11-3/8
5- 5
Q (HR)
6- 6-1/8
6-
1
6-
1
R (HR)
1-4
1- 4-1/4
S (HR)
1- 2-3/8
1- 2-1/4
t
T (HR)
0- 5-1/8
0- 4-3/4
U
(Diam)$
0-4
0- 5
0- 6
V (HS)
..
ft
0- 2-1/8
30HR140
only (no manifold on 301-113160).
*Apply to both HR and HS except as noted.
t140: 1-2-1/4;
160: 0-11-3/4
$150-lb ASA flat-face flanged water connection.
30HR,HS
100,110,120 140 I 160
W (HS)
X (HR)
Y (HR)
Z (HR)
AA "
**070: 0-1-5/8; 080: 0-1-5/8; 090: 0-2-1/8
tt100: V = W= 0-1-5/8; 110: V = 0-2-1/8, W=
0-1-5/8;
120: V = W = 0-2-1/8
$$Inlet End is 0-7-5/8
DIM.
070,080,090
0- 1-3/8
tt
1- 0-1/4
0-1.1-3/8
0- 7-7/8$$
0- 5-1/8
0- 6-3/4
0- 6-1/2
0-0
0- 3-1/4
0- 2-1/8
1- 0-7/8
0-5-1/8 0-6-5/16
Fig. 1 — Dimensions
2

Related product manuals