3
 
Physical data
 
NOTE: 
 
See unit Installation Instructions for proper installation.
 
METERING DEVICE
 
* TXV must be ordered separately when indoor coil is not equipped with a TXV. TXV is listed 
for any approved coil combination. All TXVs are bi-flow, hard shutoff.
 
UNIT SIZE 018 024 030 036 042 048 060
OPERATING WT (Lb)
 
115 166 182 182 209 250 278
 
COMPRESSOR 
Type
 
Scroll
 
REFRIGERANT
Control
 
R-22
 
TXV
 
Charge (Lb) @ 15 Ft
 
5.5 6.25 6.88 8.00 10.38 11.13 14.00
 
CONDENSER FAN
Air Discharge
 
Propeller Type, Direct Drive
Vertical
 
Air Qty (CFM)
Motor RPM (60 Hz)
 
1800
1100
2800
825
2800
825
2800
825
2800
825
2800
825
3400
1125
 
CONDENSER COIL
Face Area (Sq ft)
Fins per in
Rows
Circuits
 
12.4
20
1
2
14.8
20
1
3
18.5
20
1
3
18.5
20
1
4
16.18
20
2
5
18.5
20
2
5
22.40
20
2
6
 
CONNECTION VALVE (In. ID)
 
Sweat
 
Liquid
 
5/8 3/4 3/4 3/4 7/8 7/8 7/8
 
Vapor
 
3/8 3/8 3/8 3/8 3/8 3/8 3/8
 
REFRIGERANT TUBES 
(In. OD)
Vapor
 
5/8 3/4 3/4 3/4 7/8 1-1/8 1-1/8
 
Liquid
 
3/8 3/8 3/8 3/8 3/8 3/8 3/8
 
UNIT 
SIZE SERIES
OUTDOOR 
PISTON
INDOOR
TXV*
018
 
30 42 KSATX0601HSO
 
024
 
30 52 KSATX0601HSO
 
030
 
30 55 KSATX0601HSO
 
036
 
30 61 KSATX0601HSO
 
042
 
30 65 KSATX0601HSO
 
048
 
30 73 KSATX0701HSO
 
060
 
30 78 KSATX1001HSO
REGISTERED
ISO 9001:2000
 
CERTIFICATION APPLIES ONLY WHEN THE
COMPLETE SYSTEM IS LISTED WITH ARI.
  
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
T
O
A
R
I
A
S
C
O
M
P
L
Y
I
N
G
W
I
T
H
A
R
I
S
T
A
N
D
A
R
D
2
4
0
U
N
I
T
A
R
Y
H
E
A
T
P
U
M
P
E
Q
U
I
P
M
E
N
T
®
 
REGISTERED QUALITY SYSTEM
  
As an ENERGY STAR® 
Partner, Carrier 
Corporation has 
determined that this 
product meets the 
ENERGY STAR® guide-
lines for energy 
efficiency.
 
*
 
*
 
Refer to the combination ratings in the Product Data Digest for system combinations meeting ENERGY STAR® efficiency standards.