EasyManua.ls Logo

Carrier 38MAQB12R-1 User Manual

Carrier 38MAQB12R-1
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Specifications subject to change without notice.
Fig. 1 —Sizes 9K to 36K
NOTES: Read the entire instruction manual before starting the
installation.
Images are for illustration purposes only. Actual
models may differ slightly.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS........................................................2
INTRODUCTION ............................................................................3
ACCESSORIES................................................................................3
DIMENSIONS..................................................................................4
CLEARANCES ................................................................................7
INSTALLATION REQUIREMENTS .............................................8
INSTALLATION .............................................................................8
Step 1 - Check Equipment ................................................................8
Step 2 - Mount Unit ..........................................................................8
Step 3 - Condensate Drain Installation .............................................9
Step 4 - Refrigerant Piping ...............................................................10
Step 5 - Evacuate Coil And Tubing System .....................................13
Step 6 - Electrical Connections.........................................................14
WIRING ...........................................................................................14
ELECTRICAL DATA......................................................................15
CONNECTION DIAGRAMS ..........................................................15
START-UP .......................................................................................16
CARE AND MAINTENANCE........................................................16
TROUBLESHOOTING ...................................................................16
OUTDOOR UNIT DIAGNOSTIC GUIDES ...................................17
DUCTLESS START-UP CHECKLIST ...........................................18
Installation Instructions
38MA*R
Outdoor Unit Single Zone Ductless System
Sizes 09 to 36

Questions and Answers:

Carrier 38MAQB12R-1 Specifications

General IconGeneral
Voltage208/230V
RefrigerantR-410A
Phase1
Compressor TypeRotary
TypeMini-Split
Cooling Capacity12000 BTU/h
EER3.5 COP
Power Supply60 Hz

Summary

SAFETY CONSIDERATIONS

INSTALLATION REQUIREMENTS

Step 1 - Check Equipment

Unpack and inspect the unit for damage and verify job specifications.

Step 2 - Mount Unit

Instructions for selecting a location and mounting the outdoor unit securely.

INSTALLATION

Step 3 - Condensate Drain Installation

Details on installing the drain joint and hose for proper condensate drainage.

Step 4 - Refrigerant Piping

Provides specifications and guidelines for refrigerant piping, including lengths and pipe sizes.

Step 5 - Evacuate Coil And Tubing System

Step 6 - Electrical Connections

START-UP

TROUBLESHOOTING

Information on diagnostic codes and failure modes displayed on indoor and outdoor units.

OUTDOOR UNIT DIAGNOSTIC GUIDES

DUCTLESS START-UP CHECKLIST

Ductless Start-Up Checklist (CONT)