26
PERFORMANCE DATA (CONT.)
INSTANTANEOUS AND INTEGRATED HEATING RATINGS
40KMQ030 WITH 38QRF030
Air Temperature
Entering Indoor
Unit ° F (° C)
Indoor
Airflow
(CFM)
L --- M --- H
Item
Air Temperature Entering Outdoor Coil ° F (° C)
17 ( --- 8.3) 27 ( --- 2.8) 37 (2.8) 47 (8.3) 57 (13.9)
Instant.
Rating
Integrated
Rating
Instant.
Rating
Integrated
Rating
Instant.
Rating
Integrated
Rating
Instant.
Rating
Integrated
Rating
Instant.
Rating
Integrated
Rating
55 (12.8)
670
Cap 18.23 16.62 21.04 18.69 24.76 22.54 28.14 28.14 31.61 31.61
kW 1.97 2.18 2.35 2.42 2.86
760
Cap 18.28 16.66 21.67 19.25 25.01 22.76 28.56 28.56 32.46 32.46
kW 1.99 2.13 2.23 2.42 2.67
910
Cap 18.74 17.08 22.20 19.71 25.49 23.20 29.15 29.15 33.59 33.59
kW 1.96 2.03 2.24 2.40 2.49
60 (15.6)
670
Cap 17.74 16.18 20.67 18.36 24.38 22.19 27.96 27.96 31.66 31.66
kW 2.03 2.21 2.36 2.61 2.89
760
Cap 17.94 16.36 21.16 18.80 24.75 22.53 28.32 28.32 31.87 31.87
kW 2.06 2.19 2.34 2.49 2.82
910
Cap 18.42 16.79 21.43 19.04 24.98 22.73 28.70 28.70 33.17 33.17
kW 2.00 2.18 2.27 2.49 2.59
65 (18.3)
670
Cap 17.28 15.76 20.19 17.93 23.86 21.71 27.38 27.38 30.59 30.59
kW 2.10 2.36 2.46 2.72 3.19
760
Cap 17.67 16.11 20.56 18.26 24.31 22.12 26.80 26.80 31.89 31.89
kW 2.10 2.33 2.43 2.98 2.79
910
Cap 17.92 16.34 21.31 18.93 24.65 22.43 28.27 28.27 32.49 32.49
kW 2.10 2.20 2.35 2.59 2.70
70 (21.1)
670
Cap 16.40 14.95 20.01 17.77 23.39 21.28 26.86 26.86 30.59 30.59
kW 2.29 2.39 2.52 2.85 3.12
760
Cap 16.50 15.04 20.23 17.96 23.72 21.59 27.17 27.17 31.40 31.40
kW 2.28 2.38 2.49 2.81 2.91
910
Cap 16.60 15.14 20.86 18.53 23.79 21.65 27.40 27.40 32.16 32.16
kW 2.27 2.30 2.62 2.80 2.80
75 (23.9)
670
Cap 16.30 14.86 19.61 17.42 22.58 20.54 26.40 26.40 30.34 30.34
kW 2.30 2.45 2.73 2.89 3.10
760
Cap 16.40 14.95 19.76 17.55 23.01 20.94 26.73 26.73 30.93 30.93
kW 2.29 2.46 2.73 2.80 3.04
910
Cap 16.55 15.09 20.40 18.12 23.48 21.37 27.31 27.31 31.46 31.46
kW 2.28 2.37 2.68 2.84 2.98
80 (26.7)
670
Cap 15.77 14.38 19.06 16.93 22.55 20.52 25.80 25.80 29.76 29.76
kW 2.33 2.51 2.71 3.01 3.22
760
Cap 16.21 14.78 19.55 17.36 22.57 20.54 26.26 26.26 30.23 30.23
kW 2.30 2.50 2.77 2.89 3.08
910
Cap 16.50 15.04 19.79 17.58 23.32 21.22 26.72 26.72 30.91 30.91
kW 2.30 2.50 2.64 2.97 3.08
Indicates Rating Condition (*Integrated Capacity)
Indicates Integrated Rating
Cap --- Heating Capacity (100 Btuh), Includes indoor fan motor heat
kW --- Total Power Input, includes compressor motor power input, outdoor fan motor power input, and indoor fan motor power input
Note: Integrated Capacity is maximum (instantaneous ) capacity less the effect of frost on the outdoor coil and the heat to defrost it.
40KMC, KMQ / 38HDF, QRF