EasyManua.ls Logo

Carrier 42QHF012DS - Troubleshooting

Carrier 42QHF012DS
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57 / 78
12.Troubleshooting
12.1 Indoor unit error code explanation:
HIWALL (42QHF009DS, 42QHF012DS, 42QHF018DS)
Display
Operation lamp flash times
Timer lamp
Failure
E0
1
X
Indoor EEPROM malfunction
E1
2
X
Indoor / outdoor units communication error
E3
4
X
Indoor fan speed has been out of control
E4
5
X
Open or short circuit of T1 temperature sensor
E5
6
X
Open or short circuit of T2 temperature sensor
F1
2
O
Open or short circuit of T4 temperature sensor
F2
3
O
Open or short circuit of T3 temperature sensor
F3
4
O
Open or short circuit of T5 temperature sensor
F4
5
O
Outdoor EEPROM parameter error
F5
6
O
Outdoor fan speed out of control
F6
7
O
Open or short circuit of T2B temperature sensor
P0
1
IPM module protection
P1
2
Voltage protection
P4
5
Inverter compressor drive protection
P5
6
Mode conflict
P6
7
Low pressure protection(Just matching with
38QUS036DS4)
O light X off flash
Light Commercial series (Cassette/Duct)
NO.
MALFUNCTION
RUN
Timer
DEF
Alarm
DISPLAY
DIGITAL TUBE
1
Open or short circuit of T1 temperature sensor
X
X
X
E0
2
Open or short circuit of T2 temperature sensor
X
X
X
E1
3
Indoor / outdoor units communication error
X
X
X
E2
4
Full-water malfunction
X
X
X
E3
5
Indoor EEPROM malfunction
X
X
E4
6
IPM module protection
X
X
O
E5
7
Open or short circuit of T3 or T4 temperature sensor or
Outdoor EEPROM malfunction
O
X
X
E6
8
Outdoor fan speed has been out of control
O
X
E7
9
Indoor fan speed has been out of control
O
O
X
F5
10
Voltage protection
O
X
O
P0
11
Outdoor unit over-current protection
X
P2
12
Inverter compressor drive protection
X
X
P4
13
Mode conflict
X
O
O
P5
Flash(at 2.5Hz) Flash(at 0.5Hz) O light Xoff
Note: Digital display is only available for duct type.
Console series:
Operation
Timer
De-frost
LED STATUS
X
X
Open or short circuit of T1 temperature sensor
X
X
Open or short circuit of T2 temperature sensor

Other manuals for Carrier 42QHF012DS

Related product manuals