EasyManua.ls Logo

Carrier 48ES - OPERATING YOUR UNIT; Cooling Mode; Gas Heat Mode; MAINTENANCE AND SERVICE

Carrier 48ES
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
R
E
Q
U
I
R
E
D
C
L
E
A
R
A
N
C
E
F
O
R
O
P
E
R
A
T
I
O
N
A
ND
S
E
R
V
I
C
I
N
G
INCHES [mm]
EVAP. COIL ACCESS SIDE............................................................36.00 [914.0]
POWER ENTRY SIDE....................................................................42.00 [1066.8]
(EXCEPT FOR NEC REQUIREMENTS)
UNIT TOP .......................................................................................48.00 [1219.2]
SIDE OPPOSITE DUCTS ..............................................................36.00 [914.0]
DUCT PANEL .................................................................................12.00 [304.8] *
*MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN 12.00 [304.8] FROM
WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE.
R
E
Q
U
I
R
E
D
C
L
E
A
R
A
N
C
E
T
O
C
O
M
B
U
S
T
I
B
L
E
M
A
TL
.
INCHES [mm]
TOP OF UNIT...................................................................................14.00 [355.6]
DUCT SIDE OF UNIT.........................................................................2.00 [50.8]
SIDE OPPOSITE DUCTS ................................................................14.00 [355.6]
BOTTOM OF UNIT.............................................................................0.50 [12.7]
ELECTRIC HEAT PANEL .................................................................36.00 [914.4]
N
E
C
.
R
E
Q
U
I
R
E
D
C
L
E
A
R
A
N
C
E
S
.
INCHES [mm]
BETWEEN UNITS, POWER ENTRY SIDE ....................................42.00 [1066.8]
UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE .36.00 [914.0]
UNIT AND BLOCK OR CONCRETE WALLS AND OTHER
GROUNDED SURFACES, POWER ENTRY SIDE.........................42.00 [1066.8]
LEGEND
CG - Center of Gravity
COND - Condensor
EVAP - Evaporator
NEC - National Electrical Code
REQ’D - Required
NOTE: Dimensions are in in. [mm]
A05142
UNIT
ELECTRICAL
CHARACTERISTICS
UNIT WEIGHT
UNIT HEIGHT
IN. [MM]
“A”
CENTER OF GRAVITY
IN. [MM]
lb kg X Y Z
48ES042 208/230--1--60, 208/230--3--60, 460--3--60 401 181.9 42.98 [1092] 25.5 [647.7] 20.5 [520.7] 17.1 [434.3]
48ES048 208/230--1--60, 208/230--3--60, 460--3--60 418 189.6 42.98 [1092] 25.2 [640.1] 20.7 [525.8] 17.4 [442.0]
48ES060 208/230--1--60, 208/230--3--60, 460--3--60 446 202.3 46.98 [1193] 25.5 [647.7] 21.0 [533.4] 17.6 [447.0]
Fig. 4 -- 48ES042 --060 Unit Dimensions