EasyManua.ls Logo

Carrier 48HJD006 User Manual

Carrier 48HJD006
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Copyright 1999 Carrier Corporation Form 48HJ-11PD
Carrier has designed the Weather-
master series based on customer
needs and requests to be the most
efficient and reliable rooftop unit ever
made.
Features/Benefits
Most efficient rooftop line for
cooling using scroll compressor
technology
Most efficient rooftop line for
heating using dimpled heat
exchangers on all units
High reliability — non-corrosive
condensate pans, prepainted
cabinets and primed interior
panels, and all units are fully
protected by internal safeties
Quietest operation — all
compressors mounted on
independent vibration isolators.
Standard, belt-driven evaporator
fan motors on all units
Ease of maintenance achieved by
self diagnostics on the Integrated
Gas Controller (IGC), optional
direct digital controls, standard
size filters, tool-less filter access,
simple compressor access,
permanently lubricated fan
motors, optional disconnect
switch, optional 115-v
convenience outlet, and optional
hinged access panels
Exclusive MoistureMiser
dehumidification package — a
result of recent advances by
Carrier in controlling comfort
levels. This factory-installed
option significantly improves the
dehumidification capability of the
rooftop unit and helps control
humidity levels in the building.
48HJD/HJE/HJF
Single-Package Rooftop Units
High-Efficiency Electric Cooling/
Gas Heating
3 to 12
1
/
2
Nominal Tons
Product
Data
48HJ004-007
48HJ008-014
Question and Answer IconNeed help?

Do you have a question about the Carrier 48HJD006 and is the answer not in the manual?

Carrier 48HJD006 Specifications

General IconGeneral
BrandCarrier
Model48HJD006
CategoryHeat Pump
LanguageEnglish

Summary

Features and Benefits

Easy Maintenance and Installation

Details on unit setup, conversion, and access for maintenance.

Quiet, Efficient Operation and Dependable Performance

Highlights compressor design, fan motors, coil technology, and heat exchangers.

Serviceability

Covers hinged access panels, convenience outlets, and tool-less filter access.

Model Number Nomenclature

ARI Capacities

HEATING CAPACITIES AND EFFICIENCIES

Provides heating input, output, AFUE, and efficiency ratings for different unit models.

Physical Data

Performance Data

COOLING CAPACITIES, STANDARD UNITS

Performance data for standard units across different airflow and temperature conditions.

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS

Data on fan speed, motor horsepower (Bhp), and airflow at different static pressures for vertical units.

Electrical Data

STANDARD MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET

Electrical data for standard motor units without the convenience outlet option.

Controls

Operating sequence for 48HJ004-007 units

Details the cooling and heating operational sequences for smaller unit sizes.

Cooling, units with EconoMi$er

Describes the cooling control logic when an EconoMi$er is installed.

Application Data

MoistureMiser dehumidification package

Details the benefits and operation of the MoistureMiser package for humidity control.

Applications

Lists common rooftop unit applications susceptible to high humidity issues.

Guide Specifications

Part 1 - General

Covers system description, quality assurance, and delivery requirements for the rooftop units.

Part 2 - Products

Details standard equipment features including cabinet, fans, compressors, and coils.

I. Controls and Safeties:

Specifies unit controls, safety devices, and protection features for reliable operation.

M. Special Features:

Lists optional special features such as Direct Digital Controls and Roof Curbs.