UNIT
48VG(-,N)A60130
Table 11 - Dry Coil Air Delivery* - Horizontal and Downflow Discharge - Unit 48VG-A 208/230 VAC Models (Cont)
HEATING RISE MOTOR WIRE EXTERNAL STATIC PRESSURE (IN. W.C.)
RANGE SPEED COLOR 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Low 1
35 - 65°F Low Stage,
35 - 65°F High Stage
Med-Low 3
Medium
Med-High 2
High 4
Blue
Pink
Red
Orange
Black
0.9 1
CFM 1271 1229 1177 1121 1066 1027 974 942 887 839
BHP 0.19 0.20 0.21 0.23 0.24 0.25 0.26 0.27 0.28 0.29
Low Stage Heat Rise °F 49 51 53 56 59 61 64
NA NA NA
(°C) (27) (28) (30) (31) (33) (34) (36)
High Stage Heat Rise °F
NA NA NA NA NA NA NA NA NA NA
(°C)
CFM 1340 1299 1240 1191 1139 1091 1050 1001 952 895
BHP 0.22 0.23 0.24 0.25 0.26 0.28 0.29 0.30 0.31 0.32
Low Stage Heat Rise °F 47 48 51 53 55 57 60 63
NA NA
(°C) (26) (27) (28) (29) (31) (32) (33) (35)
High Stage Heat Rise °F
NA NA NA NA NA NA NA NA NA NA
(°C)
CFM 1686 1650 1617 1576 1544 1503 1468 1433 1393 1356
BHP 0.42 0.44 0.45 0.46 0.48 0.49 0.51 0.52 0.53 0.55
Low Stage Heat Rise °F 37 38 39 40 41 42 43 44 45 46
(°C) (21) (21) (22) (22) (23) (23) (24) (24) (25) (26)
High Stage Heat Rise °F 57 58 59 61 62 64 65
NA NA NA
(°C) (32) (32) (33) (34) (35) (35) (36)
CFM 1878 1844 1805 1762 1731 1693 1655 1616 1570 1532
BHP 0.50 0.52 0.53 0.54 0.56 0.57 0.59 0.60 0.64 0.63
Low Stage Heat Rise °F NA NA 35 36 36 37 38 39 40 41
(°C) (19) (20) (20) (21) (21) (22) (22) (23)
High Stage Heat Rise °F 51 52 53 54 55 57 58 59 61 63
(°C) (28) (29) (30) (30) (31) (31) (32) (33) (34) (35)
CFM 1934 1900 1855 1815 1778 1737 1695 1656 1606 1528
BHP 0.59 0.61 0.62 0.64 0.65 0.67 0.68 0.70 0.70 0.68
Low Stage Heat Rise °F NA NA NA 35 35 36 37 38 39 41
(°C) (19) (20) (20) (21) (21) (22) (23)
High Stage Heat Rise °F 50 50 52 53 54 55 57 58 60 63
(°C) (28) (28) (29) (29) (30) (31) (31) (32) (33) (35)
Notes:
1 Factory-shipped low stage cooling speed
2 Factory-shipped high stage cooling speed
3 Factory-shipped low stage gas heating speed
4 Factory-shipped high stage gas heating speed
Allowable High Stage Enhanced Dehumidification Cooling Speed
"NA" = Not allowed for particular heating speed