A Guide to Operating and Maintaining Your
Single-Packaged Electric Heat Pump Unit
NOTE: Read the entire instruction manual be%re starting the
installation.
SAFETY CONSIDERATIONS
Installation and servicing of air:conditioning equipment can be
hazardous &/e to system pressure and electrical components Only
trained and qualified personnel should install, repair, or service
air-conditioning equipment
Untrained personnel can perfom_ basic maintenance fonctions of
cleaning coils and filters. All other operations should be perfbrmed
by tlained service personnel. When working on air-conditioning
equipment, observe precautions in the literature, tags, and labels
attached to the unit, and other safety precautions that may apply.
Follow all safe V codes. Wear safety" glasses and work gloves. Use
quenching cloth fbr unbrazing operations. Have fire extinguisher
available for all brazing operations.
Recognize safety information. This is the saf?ty=alert symbolfi._.
When you see this symbol on the product or in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNfNG, CAU=
TION, and NOTE. Danger identifies the most serious hazards,
which will result in severe personal injury- or death. Warning
indicates a condition d'mt could cause serious personal it{jury," or
death. Caution is used to identify unsafe practices, which would
result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
Note to Installer:This manual should be left with the equipment
user,
Do not store or use gasoline or other flamnmble vapors and
liquids in the vicinity' of this or any other appliance. Failure to
follow this warning could result in fire, serious injury, or
death
Do not use this unit if any part has been under water.
Imntediately call a qualified service technician to inspect the
unit and to replace any part of the cormol system which has
been under water Failure to follow this warning could result
in electrical shock, fire, serious ir_jury, or death.
Before performing recommended maintenance, be sure the
main power s_itch to unit is turned off. Electric shock could
cause serious i11iury or death.
C99064
Fig. 1--Unit 50XZ
b, Select temperature and set SYSTEM switch or MODE
control to desired mode
2 To shut unit off:
NOTE: If the unit is being shut down because of" a malfunction,
call your dealer as soon as possible.
a. Set system SWITCH or MODE control to OFF.
b. Turn off the electrical power supply to unit.
OPERATING YOUR HEAT PUMP
]"he operation of yore heat pump system is controlled by the
indoor them_ostat. Yott simply adjust the them_ostat and it
maintains the indoor temperature at the level you selecL Most
thermostats of heat pump systems have 3 controls: a temperature
conhol selector, a FAN control, and a SYSTEM or MODE control.
Refer to your thermostat owner's manual for more infbmmtion
To better protect your investment and to eliminate unnecessao,-
service calls, familiarize yourself with the _k_llowing facts:
1. During heating, increasing the thermostat setting more than
2°F may cause the supplemental heaters to be turned on for a
short period of time to satisfy the themmstat. Needless use of
the supplementary heat reduces potential energy savings.
STARTING OR SHUTTING UNiT OFF
1, To start the trait:
a. Turn on the electrical po_er supply to unit.
Nanufacturer reserves the r}ght to discontinue, or change at any time, specifications or designs wRhout notice and without incurring oNigations.
PC 101 Catalog No 535-00069 Printed in US.A. Form OM50-33 Pg 1 4-03 Replaces: New
Question and Answer IconNeed help?

Do you have a question about the Carrier 50XZ Guide and is the answer not in the manual?

Summary

Safety Considerations

General Safety Precautions

Key safety warnings and precautions for operating and servicing the unit, including signal words.

Unit Operation

Starting and Shutting Down the Unit

Procedures for powering the unit on and off, including thermostat settings.

Operating Modes

Explains cooling, heating, supplemental, defrost, and emergency heat modes.

Maintenance and Care

Routine Maintenance Tasks

Describes basic maintenance steps for filters and general care.

Dealer Recommended Maintenance

Lists inspections and services best performed by a qualified technician.

Troubleshooting Before Calling Service

Checks for common issues related to heating/cooling and unit operation.

Troubleshooting and Service

In Case of Trouble

Guidance on actions to take if unit performance remains unsatisfactory.

Summary

Safety Considerations

General Safety Precautions

Key safety warnings and precautions for operating and servicing the unit, including signal words.

Unit Operation

Starting and Shutting Down the Unit

Procedures for powering the unit on and off, including thermostat settings.

Operating Modes

Explains cooling, heating, supplemental, defrost, and emergency heat modes.

Maintenance and Care

Routine Maintenance Tasks

Describes basic maintenance steps for filters and general care.

Dealer Recommended Maintenance

Lists inspections and services best performed by a qualified technician.

Troubleshooting Before Calling Service

Checks for common issues related to heating/cooling and unit operation.

Troubleshooting and Service

In Case of Trouble

Guidance on actions to take if unit performance remains unsatisfactory.

Overview

The Carrier 50XZ Single-Packaged Electric Heat Pump Unit with Puron® (R-410A) Refrigerant is a comprehensive heating and cooling solution designed for residential and commercial applications. This unit integrates both heating and cooling functions into a single package, utilizing a heat pump system for energy-efficient operation.

Function Description:

The primary function of the 50XZ unit is to provide year-round indoor comfort by heating or cooling the air as needed. In cooling mode, it extracts heat from the indoor air and expels it outdoors, lowering the indoor temperature. In heating mode, it reverses the process, extracting heat from the outdoor air and transferring it indoors, even in cold weather. The unit is equipped with Puron (R-410A) refrigerant, an environmentally friendly alternative to older refrigerants. Supplemental electric heaters are included to assist the heat pump during extremely cold conditions or when a rapid temperature increase is required, ensuring consistent comfort. The system is controlled by an indoor thermostat, allowing users to set desired temperatures and operating modes (COOL, HEAT, OFF, FAN).

Important Technical Specifications:

The manual provides specific filter sizes for different unit sizes, indicating the importance of proper filtration for efficient operation and air quality.

  • Unit Size 50XZ024-030: Requires a 20x20x1 filter.
  • Unit Size 50XZ036: Requires a 20x24x1 filter.
  • Unit Size 50XZ042-060: Requires a 24x30x1 filter.

Clearance requirements are critical for proper functioning and safety:

  • Top Clearance: 48 inches.
  • Side Clearance: At least 36 inches (except power entry side and duct side).
  • Power Entry Side Clearance: 42 inches.
  • Duct Side Minimum Clearance: 12 inches.

These clearances ensure unobstructed airflow to the condenser coil, which is vital for the unit's efficiency and longevity. The unit operates under system pressure, and proper refrigerant handling is emphasized, requiring all refrigerant to be recovered before system repair or disposal.

Usage Features:

The 50XZ unit is designed for user-friendly operation through an indoor thermostat.

  • Starting the Unit: Turn on the electrical power supply and select the desired temperature and mode (COOL or HEAT) on the thermostat.
  • Shutting Off the Unit: Set the system switch or mode control to OFF and then turn off the electrical power supply.
  • Operating Modes:
    • Cooling Mode: The unit runs until the indoor temperature reaches the selected level.
    • Heating Mode: The unit runs until the room temperature reaches the selected level.
    • Supplemental Heat: Automatically activates when the heat pump needs additional assistance to maintain comfort, especially on cold days. Over-setting the thermostat by more than 2°F can trigger unnecessary supplemental heat, reducing energy savings.
    • Defrost Mode: Automatically melts ice or frost that forms on the outdoor coil during winter heating operation. This is a normal function, and steam or fog rising from the outdoor unit during this cycle is expected. The defrost cycle starts at a preset time interval (default 30 minutes, adjustable to 60, 90, or 120 minutes) if ice buildup is sufficient to impede heating operation. It lasts for a maximum of 10 minutes or until the ice is melted.
    • Emergency Heat Mode: Allows the supplemental heating source to operate independently if the heat pump requires servicing, ensuring continuous warmth.

Maintenance Features:

Regular maintenance is crucial for the unit's efficiency, reliability, and longevity. Both owner-performed and dealer-performed maintenance tasks are outlined.

Owner-Performed Maintenance (with caution):

  • Air Filters: Check at least every 3-4 weeks and clean or replace when dirty. Dirty filters can stress the blower motor and lead to overheating. The unit must never be operated without filters. Filters can be located in return air filter grilles or an accessory filter rack within the unit. When replacing, ensure the correct size and type of filter are used, and note the airflow direction.
  • Condenser Fan: Keep the fan free of obstructions. Do not poke objects into the revolving fan blades to avoid injury or damage.
  • Safety Precautions: Always turn off the main electrical power switch before performing any maintenance to prevent electric shock. Be aware of sharp sheet metal parts and screws when accessing internal components.
  • Coil Cleaning: Inspection and cleaning of outdoor and indoor coils.
  • Drain Pan Cleaning: Inspection and cleaning of the indoor coil drain pan.
  • Blower System: Inspection and cleaning of blower wheel housing and motor.
  • Ductwork Inspection: Inspection of all supply-air and return-air ducts for leaks, obstructions, and insulation integrity.
  • Unit Base and Casing: Inspection for cracks, gaps, or deterioration.
  • Electrical System: Inspection of all electrical wiring and components for proper connection.
  • Refrigerant Circuit: Inspection for leaks and pressure-check to determine appropriate refrigerant charge. This requires specialized equipment and trained personnel.
  • Compressor Oil Level: Inspection to ensure proper oil level.
  • Operational Check: A full operational check of the unit to determine working conditions and make necessary adjustments or repairs.

The manual also emphasizes troubleshooting steps for common issues before calling for service, such as checking airflow, dirty filters, blocked grilles, and thermostat settings. It advises recording the unit's model and serial numbers for quick reference during service calls. The manufacturer reserves the right to discontinue or change specifications and designs without notice.