Table6--ApprovedCombustion=AirandVentPipe,Fittingand CementMaterials
ASTM SPECBFBCATION
MATER_AL PiPE FITTtNGS SOLVENT CEMENT AND PRBMERS
(_',_ARKED ON MATER_AL)
DESCRBPTION
D1527
D1785
D2235
D2241
D2466
D2458
D2564
D2661
D2655
F438
F441
F442
F493
F628
F656
F891
ABS Pipe --
PVC Pipe --
For ABS -- --
PVC Pipe --
PVC -- Fittings
ABS -- Fittings
For PVC -- --
ABS Pipe Fittings
PVC Pipe Fittings
CPVC -- Fittings
CPVC Pipe --
CPVC Pipe --
For CPVC -- --
ABS Pipe --
For PVC -- --
PVC Pipe --
Solvent
Cement
Solvent
Cement
Solvent
Cement
Primer
Schedule-40
Schedule-40
For ABS
SDR-21 & SDR-26
Schedule-4O
Schedule-40
For PVC
DWV at Schedule-40 IPS sizes
DWV
Schedule-40
Schedule-40
SDR
For CPVC
Cellular Core DWV at Schedule-40 IPS sizes
For PVC
Cettular Core Schedule-40 & DWV
VENT PiPE
PiPE
HORIZONTALTO ROOF HORIZONTAL TO SIDEWALL
COMBUSTION-AIRPIPE "J',_
COMBUSTION-AIR PIPE _ ..................................3 _--
F VENT PIPE
VERTICAL TO ROOF VERTICAL TO SIDEWALL
NOTE: A 12 in. minimum offset pipe section is recommended with
short (5 to 8 ft) vent systems. This recommendation is to reduce
excessive condensate droplets from exiting the vent pipe
Fig. 34_Short Vent (5 to 8 Ft) System
A96230
27