EasyManua.ls Logo

Carrier 58MCB040 User Manual

Carrier 58MCB040
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
58MCB
4-WAY MULTIPOISE FIXED-CAPACITY
CONDENSING GAS FURNACE
Input Rates: 40,000 thru 138,000 Btuh
Product Data
High Efficiency and
Flexibility Designed to Meet
the Needs of New Homes
The model 58MCB combines high
efficiency with flexibility to meet the
changing needs of new home
construction. The unique 4-way,
multipoise design of the 58MCB allows
for installation in upflow, downflow,
horizontal left, and horizontal right
orientations, meaning it is perfect for a
variety of installation applications. With
the exception of the 140 size unit, all
sizes of the 58MCB can be installed in a
manufactured (mobile) home when the
optional kit is used and in installations
with elevations up to 10,000 ft (140
size unit limitation 7,000 ft). The
furnace is factory configured for upflow
application but can easily be made ready
for downflow or horizontal installation.
With the exception of the 140 size, all
sizes can be installed with 2-pipe or
1-pipe venting. The 140 size can be
installed only as a 2-pipe system.
Horizontal applications offer the ad-
vantage of reduced space requirements
by locating the furnace in an attic or
crawlspace, freeing space formerly ded-
icated to a furnace or utility room.
The 58MCB is specifically designed
to meet the needs of home builders and
new home owners. Home builders
benefit from the 58MCB’s unmatched
flexibility and by building a reputation
of using quality appliances in homes.
Home owners benefit by energy savings
from one of the most important home
appliances.
The components of the 58MCB
represent the finest in the industry. Hot
surface ignition (HSI) and a control
center provide reliable and efficient
ignition. The combustion inducer is
unique in that efficient operation is
Question and Answer IconNeed help?

Do you have a question about the Carrier 58MCB040 and is the answer not in the manual?

Carrier 58MCB040 Specifications

General IconGeneral
Model58MCB040
TypeGas Furnace
Heating Capacity40, 000 BTU
Efficiency Rating80% AFUE
Blower MotorMulti-Speed
Fuel TypeNatural Gas
StagesSingle Stage
Input BTU40, 000 BTU
Blower Motor TypePSC
Ignition TypeHot Surface Ignition
Filter Size16 x 25 x 1 inches
Weight120 lbs
Vent Diameter4 inches

Summary

Product Data Overview

High Efficiency and Flexibility

Describes the 58MCB furnace's adaptability for new homes, multipoise design, and varied installation needs.

58MCB Features and Benefits

Advanced Components and Technology

Details Serpentuff coating, Power Heat Igniter, Control Center, and warranties for reliability and performance.

Installation Clearances

Clearance to Combustibles

Specifies minimum required clearances from the furnace to combustible materials for safe installation in all positions.

Ventilation and Piping Requirements

Combustion-Air and Vent Piping Data

Provides tables for pipe diameter and number of 90° elbows for direct/non-direct vent applications based on altitude.

Electrical Data and Wiring Schematic

Unit Electrical Specifications

Lists unit voltage, operating range, maximum amps, wire size, fuse size, and transformer rating.

Guide Specifications Summary

General System Description

Outlines the furnace type, gas usage, and primary components for the 58MCB model.