Carrier Non-Programmable Thermostats - Two-Speed Heat Pump with Variable-Speed (FK4 C, FV4 A, 40 FKA) Fan Coil; Single-Speed Packaged Air Conditioner with Single-Speed Electric Heat (50 SS, SX, ZP); Single-Speed Packaged Air Conditioner with Single-Stage Gas Furnace (48 SS, SX); Single-Speed Packaged Air Conditioner with 2-Stage Electric Heat (50 SS, SX, ZP)

Carrier Non-Programmable Thermostats
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 20—Single-Speed Packaged Air Conditioner
with Single-Speed Electric Heat (50SS, SX, ZP)
A98470
SPLICE
BOX
RED
YEL
WHT
See notes 8 and 12
HEATER
CONTROL BOX
GRN
BRN
BRN
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
C
R
G
W/W1
Y/Y2
MODEL AC
THERMOSTAT
Fig. 18—Two-Speed Heat Pump with
Variable-Speed (FK4C, FV4A, 40FKA) Fan Coil
A98467
24 VAC HOT
24 VAC COMM
FAN
COOL/HEAT
STAGE 2
HEAT STAGE 3
R
Y/Y2
R
C
C
C
R
MODEL 2S
THERMOSTAT
EASY SELECT
TERMINAL BOARD
TWO-SPEED
HEAT PUMP
J1 JUMPER
J2 JUMPER
See notes 5, 7, 8, 10, and 11
G
G
Y/Y2
DH
W/W1 W1
W2W2
RVS COOLING
COOL/HEAT
STAGE 1
N/A
OUTDOOR
SENSOR
CONNECTION
Y1
S1
S2
B
Y1
Y1
Y2
O/W2
OO
Fig. 21—Single-Speed Packaged Air Conditioner
with 2-Stage Electric Heat (50SS, SX, ZP)
A98471
B
S1
S2
SPLICE
BOX
YEL
WHT
PNK
See notes 2, 8, 9, and 12
O/W2
HEAT STAGE 2
N/A
Y1
N/A
OUTDOOR
SENSOR
CONNECTION
HEATER
CONTROL BOX
GRN
VIO
BRN
BRN
RED
RED
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
C
R
G
W/W1
Y/Y2
MODEL HP
THERMOSTAT
RED (TRAN)
Fig. 19—Single-Speed Packaged Air Conditioner
with Single-Stage Gas Furnace (48SS, SX)
A98469
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
C
R
G
W/W1
Y/Y2
MODEL AC
THERMOSTAT
SPLICE
BOX
RED
BRN
WHT
YEL
GRN
See note 8
9

Table of Contents