23
A07220
Fig. 16 -- Reattach Display Module
9. Turn on power to equipment. On power up, all display segments will light
for 5 sec. For the next 5 sec a 2--digit code appears on large display which
identifies Thermidistat Control configuration. Refer to Option 33.
a. AC 1--stage air conditioner with furnace or fan coil
b. HP 1--stage heat pump with fan coil
c. A2 2--stage air conditioner with furnace or fan coil
d. H2 2--stage heat pump with fan coil
e. hh Hybrid Heat system with 1--stage heat pump
f. h2 Hybrid Heat system with 2--stage heat pump
g. H heating only system
h. C cooling only system