17
Fig. 21 — Cooling Charging Charts - 50KCQA06
-1.1 1.7 4.5 7.2 10.0 12.8 15.6 18.3 21.1 23.9 26.7 29.4 32.2
552
620
689
758
827
896
965
1034
1103
1172
1241
80
90
100
110
120
130
140
150
160
170
180
30 35 40 45 50 55 60 65 70 75 80 85 90
Suction Line Pressure (PSIG / Kpa)
Suction Line Temperature (°F / °C)
CHARGING CHART -
R-410A REFRIGERANT
COOLING MODE - OUTDOOR FAN MUST BE RUNNING
48KC000273
A
OUTDOO
R
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24
A
OUTDOO
R
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24
A
OUTDOO
R
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24
OUTDOO
R
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24
A
OUTDOO
R
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24
A
OUTDOOR
TEMP
°F / °C
115 / 46
105 / 41
95 / 35
85 / 29
75 / 24