INTRODUCTION
RecyclingequipmentmeetingSAEstandardsJ1990andJ2210isdesignedtoextractandrecyclerefrigerantsthat
havebeeninmobileairconditioningsystemsonly.
R134Arefrigerantthatalsoisusedinnon-mobilesystemsmay
introducecontaminantstotherefrigerantthatequipmentmeetingSAEJ1990andJ2210cannotremove.Thisequip-
mentisnotintendedforuseonnon-mobilesystems.
UsingExtractionEquipment
Extractionequipmentisrelativelysmallandeasilyportable.Itisbestusedifashopmustservicevehicles,suchas
agriculturaloroff-highwayequipment,thatcannoteasilybebroughtintotheshop.Itisalsoconvenientforshopsthat
mustdealwithavarietyofdifferentrefrigeranttypesandexchangerecoveredrefrigerantatsomecentrallocation.
Alwaysuseextractionequipmentonthoserefrigerantsforwhichitwasdesigned.Thelubricants,hoses,andsealsin
thisequipmenthavebeendesignedtoworkwithonlyonerefrigerant.
Tohelpavoidamix-upofserviceequipmentandrefrigerants,equipmenthosesdesignedforusewhicheachrefrig-
erantareeasilyidentiable.Newservicehosesusedwith
R134Amusthaveablackstripealongthehoselengthand
carrythedesignation"SAEJ2196/R134A"(hoseslabeled"SAEJ2196"andlackingtheblackstripewereusedfor
R12.)
Ifyouuseextractionequipmentandsendyourrecoveredrefrigeranttoareclamationfacility,reclaimedrefrigerantyou
purchasemustmeettheAirConditioningandRefrigerationInstitutestandardsofpurity(ARIStandard700-88).This
willensurethattherefrigerantyouareusingnotonlymeetsthepurityrequirementsofSAEJ1991(forR12)ORJ2099
(for
R134A),butalsothatitdoesnotcontainincompatiblelubricantsorothercontaminantsfromnon-automotiveair
conditioningsystems.
UsingRecyclingEquipment
Recyclingequipmentextractsandremovescommoncontaminantsfromrefrigerants.Recyclingequipmentdesigned
andcertiedtomeetSAEstandardscanmakerefrigerantrecoveryfrommobileairconditioningsystemssuitablefor
reuseinautomotiveairconditioningsystems.Likeextractionequipment,SAEstandardsrequirethateachpieceof
recyclingequipmentbededicatedtoasinglerefrigerant.
NOTICE:Onlyequipmentcapableofrecoveringandcleaning
R134AtomeetSAEJ2099puritylevelscarriesalabel
withthephrase"DesigncertiedbyUnderwriters"Laboratories,Inc.forcompliancewithSAEJ2099.
TheUnderwriters'Laboratorieslabelmustbespecicthattheequipmentis"designcertied"fortheSAEJ2099stan-
dard.Ifnot,itcertiesonlythatthemachineisfreeofreasonableshockorotherelectricalhazardstotheuser.
Recyclingvs.Reclaiming
Recycledrefrigeranthasbeenrecoveredfromamobileairconditioningsystemandiscleanedbythesameshop
thatrecoveredittomeetJ2099forR134A.Theequipmentdesignedtorecyclerefrigerantintheshopenvironment
removesonlycontaminantspickedupduringtheoperationofamobileairconditioningsystem.
Refrigerantthatiseitherproperlyrecycledorreclaimedisadequateforuseinmobileairconditioningsystems.
4785194503/02/2016