INTRODUCTION
Farmall40Farmall45Farmall50
COOLINGSYSTEM
Type.......PressurizedLiquidwith
RecirculatingBypass
PressurizedLiquidwith
RecirculatingBypass
PressurizedLiquidwith
RecirculatingBypass
WaterPump:
Type......
CentrifugalCentrifugalCentrifugal
Drive.......V-BeltV-Belt
Belt.
Deection......10-15mm(7/16-9/16in)
when9-11kg(20-25lb)
thumbpressureisapplied
midwaybetweenbelt
pulleys
10-15mm(7/16-9/16in)
when9-11kg(20-25lb)
thumbpressureisapplied
midwaybetweenbelt
pulleys
10-15mm(7/16-9/16in)
when9-11kg(20-25lb)
thumbpressureisapplied
midwaybetweenbelt
pulleys
FanDiameter....
410mm(16.1in)410mm(16.1in)410mm(16.1in)
NumberofFanBlades.
.....
666
Thermostat:
StarttoOpen....80°C(176°F)80°C(176°F)80°C(176°F)
FullyOpen....95°C(203°F)95°C(203°F)95°C(203°F)
RadiatorCap....0.9bar(13psi)0.9bar(13psi)0.9bar(13psi)
Antifreeze.......EthyleneGlycolEthyleneGlycolEthyleneGlycol