INTRODUCTION
Coolantsolution
Putonlyethylene-glycolcoolantsolutioninthecoolingsystem.Usegoodqualityethylene-glycolthathasahigh
boilingpointwithnoadditivestopreventleakage.Donotusenon-approvedanti-rustadditives.Anti-rustadditives
andethylene-glycolcanmixandworkagainsteachother,reducinganti-corrosionprotection,formingdepositsinthe
coolingsystem,andcausingdamagetothecoolingsystemandradiator.Contactyourdealerwhocansupplyyou
withthesuitablecoolantsolution.
Anti-freeze/Anti-corrosion
Useanti-freezeinallseasonstoprotectthecoolingsystemfromcorrosionandriskoffreezing.Forareaswherethe
ambienttemperatureisover-36°C(-32.8°F)useablendof50%ethylene-glycolbasedanti-freeze.
Forareaswherethetemperatureisbelow-36°C(-32.8°F)-itisadvisabletouseablendof40%waterand60%
anti-freeze.
Fuel
Usedieselfuelsuitablefortheambienttemperatureconditions(ASTM-D-975).
UsefuelwhichistoASTM(AmericanSocietyforT estingandMaterials)D975standard.
UsegradeNo.2fuel.Theuseofothertypesoffuelcanresultinalossofpoweroftheengineandmaycausehigh
fuelconsumption.
Inverylowambienttemperatures,useamixtureoffuelsNo.1andNo.2asnecessary.Consultyourfuelsupplier
forappropriatefuelsupply.
Ifthetemperaturefallsbelowthefuelcloudpoint(pointatwhichwaxbeginstoform)thewaxcrystalswillcausepower
lossorwillpreventtheenginefromstarting.
Incoldweather,llthefueltankattheendoftheday'sworkinordertopreventtheformationofcondensation.
Fuelstorage
Prolongedstorageoffuelcanleadtotheaccumulationofimpuritiesandcondensationinthefuel.Enginetroublecan
oftenbetracedtothepresenceofwaterinthefuel.
Thestoragetankmustbeplacedoutsideandthetemperatureofthefuelshouldbekeptaslowaspossible.Drainoff
waterandimpuritiesregularly.
Hydraulicuid
CaseAkcelaHy-TranUltrahydraulicuidisspecicallydesignedforhighpressureapplicationsandforCasehydraulic
systems.YourCaseDealercanprovidehydraulicuidtofullldifferentclimate/temperatureconditions.Refertothe
chartsatthebeginningofthissection.
Transmissioncomponentoil
Extremepressureoilshouldbeusedforenclosedtransmissioncomponents.Chooseanoilthatismanufactured
foryourclimate/temperatureconditionssuchasCaseNexploreorCNHF200A.Seechartsatthebeginningofthis
section.
Grease
Thetypeofgreasetousedependsonambienttemperaturesuchas:CaseAkcelaMolydisuldeGrease
Environment
Beforeyouservicethismachineanddisposeofoil,uids,andlubricants,obeyenvironmentalregulations.Donot
drainoiloruidsontothegroundorintocontainersthatleak.Checkwithyourlocalenvironmental,recyclingcenter
oryourdealerforcorrectdisposalinformation.