EasyManua.ls Logo

Case 721G Stage V - Fuel Pre-Filter - Replace

Case 721G Stage V
522 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-MAINTENANCE
Fuelpre-lter-Replace
WARNING
Fuelvaporsareexplosiveandammable.
Donotsmokewhilehandlingfuel.Keepfuelawayfromamesorsparks.Shutoffengineandremove
keybeforeservicing.Alwaysworkinawell-ventilatedarea.Cleanupspilledfuelimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0904A
Replacethepre-lterevery500hoursthereafterormoreoftenifconditionssorequireoriffuelqualityispoor.
Prioroperation:
Keepallnon-authorizedpersonnelclearofthearea.Parkthemachineonarm,levelsurfaceinneutralwiththe
parkingbrakeapplied.Lowerthebucket/attachmenttotheground.Turnofftheengine.Installthetransport/service
linkintothelockedposition.
Drainfuelpreltercondensation
1.Opentheenginehood.Locatethepre-lterintheen-
ginecompartmentontheright-handsideofthema-
chine.
LEIL18WHL1173AA1
2.Removethewatersensorconnectorfromthebottom
ofthepre-lter.
LEIL18WHL1173AA2
3.Openthedrainvalveonthefuelpre-lterbyturning
counterclockwisetwoorthreeturns.
4.Drainthewaterand/orcontaminantsfromthepre-lter
intoasuitablecontaineruntilcleanfuelows.
NOTICE:Donotallowfueltospillonengineorground.
NOTE:theWaterinFuel(WIF)sensorisonthedrainvalve
onthefuelpre-lter.
LEIL18WHL1172AA3
7-93