EasyManua.ls Logo

Casio CLASSPAD 330 3.04 - Page 426

Casio CLASSPAD 330 3.04
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20090601
7-9-3
Tests
Calculation Result Output
μ
x
0 : test condition
z
:
z
value
p
:
p
-value
M
: sample mean
s
x
: sample standard deviation (Displayed only for list format.)
n
: sample size
Example
Mean : 131
Sample size : 10
Population standard deviation : 19
Assumed population mean : 120
Statistics Wizard Operation
(1) On the menu bar, tap [Calc] and then [Test].
(2) Select [One-Sample ZTest] and [Variable],
and then tap [Next >>].
(3) Select the
μ
condition [>] and input values.
(4) Tap [Next >>].
(5) To display the graph, tap
.
S
Program, eActivity or Main Application
Command: OneSampleZTest
:
Command Syntax
Syntax 1 (list format)
μ
condition”,
μ
0
value,
σ
value, List, Freq (or 1)
* “Freq” can be omitted. Doing so sets “1” for “Freq”.
Syntax 2 (parameter format)
μ
condition”,
μ
0
value,
σ
value,
M
value,
n
value
Input Example:
Syntax 1 (list format)
OneSampleZTest “
x
”,0,1,list1,1
Syntax 2 (parameter format)
OneSampleZTest “>”,120,19,131,10

Table of Contents

Related product manuals