All lead-acid batteries contain sulfuric acid which
can burn the skin and clothing. Always wear a
face shield and protective clothing when working
on or near batteries.
1. Remove the filler caps. Maintain the electrolyte
level to the “FULL” mark on the battery.
If the addition of water is necessary, use distilled
water. If distilled water is not available use clean
water that is low in minerals. Do not use artificially
softened water.
2. Check the condition of the electrolyte with the
245-5829 Coolant Battery Tester Refractometer.
3. Keep the batteries clean.
Clean the battery case with one of the following
cleaning solutions:
• A mixture of 0.1 kg (0.2 lb) of baking soda and
1 L (1 qt) of clean water
• A mixture of 0.1 L (0.11 qt) of ammonia and 1 L
(1 qt) of clean water
Thoroughly rinse the battery case with clean
water.
Use the 1U-9921 Battery Service Tool to clean
the battery terminals. Use a wire brush to clean
the cable clamps. Clean the items until the
surfaces are bright or shiny. DO NOT remove
material excessively. Excessive removal of
material can cause the clamps to fit improperly.
Coat the clamps and the terminals with 5N-5561
Silicone Lubricant, petroleum jelly or MPGM.
i01492654
Battery or Battery Cable -
Disconnect
SMCS Code: 1402-029
The battery cables or the batteries should not be
removed with the battery cover in place. The bat-
tery cover should be removed before any servic-
ing is attempted.
Removing the battery cables or the batteries with
the cover in place may cause a battery explosion
resulting in personal injury.
1. Turn the start switch to the OFF position. Turn the
ignition switch (if equipped) to the OFF position
and remove the key and all electrical loads.
2. Disconnect the negative battery terminal at the
battery that goes to the start switch. Ensure that
the cable cannot contact the terminal. When four
12 volt batteries are involved, the negative side of
two batteries must be disconnected.
3. Tape the leads in order to help prevent accidental
starting.
4. Proceed with necessary system repairs. Reverse
the steps in order to reconnect all of the cables.
i05793911
Cooling System Coolant
(DEAC) - Change
SMCS Code: 1350-070; 1395-044
Clean the cooling system and flush the cooling
system before the recommended maintenance
interval if the following conditions exist:
• The engine overheats frequently.
• Foaming is observed.
• The oil has entered the cooling system and the
coolant is contaminated.
• The fuel has entered the cooling system and the
coolant is contaminated.
NOTICE
Use of commercially available cooling system
cleaners may cause damage to cooling system com-
ponents. Use only cooling system cleaners that are
approved for Caterpillar engines.
Note: Inspect the water pump and the water
temperature regulator after the cooling system has
been drained. This procedure is a good opportunity
to replace the water pump, the water temperature
regulator, and the hoses, if necessary.
Drain
Pressurized System: Hot coolant can cause seri-
ous burns. To open the cooling system filler cap,
stop the engine and wait until the cooling system
components are cool. Loosen the cooling system
pressure cap slowly in order to relieve the
pressure.
1. Stop the engine and allow the engine to cool.
Loosen the cooling system filler cap slowly in
order to relieve any pressure. Remove the cooling
system filler cap.
108
SEBU7125-13
Maintenance Section
Battery or Battery Cable - Disconnect