Engine Stopping
i06171418
Emergency Stopping
SMCS Code: 1000; 7418
NOTICE
Emergency shutoff controls are for EMERGENCY
use ONLY. DO NOT use emergency shutoff devices
or controls for normal stopping procedure.
Ensure that any components for the external system
that support the engine operation are secured after
the engine is stopped.
Emergency Stop Button (If
Equipped)
Illustration 92 g03835626
Typical emergency stop symbol located near the
emergency stop button
The emergency stop button is in the OUT position for
normal engine operation. Push the emergency stop
button. The engine will not start when the button is
locked. Turn the button clockwise in order to reset.
Refer to Operation and Maintenance Manual,
“Features and Controls” for the location and the
operation of the emergency stop button.
i02302747
After Stopping Engine
SMCS Code: 1000
• Check the engine crankcase oil level. Maintain the
oil level between the “ADD” and “FULL” marks on
the “ENGINE STOPPED” side of the oil level
gauge. Complete all of the lubrication
recommendations that are listed in Special
Publication, SEBU6251, “Caterpillar Commercial
Diesel Engine Fluids Recommendations”.
• If necessary, perform minor adjustments. Repair
any leaks and tighten loose bolts.
• Note the service hour meter reading. Perform the
maintenance that is in the Operation and
Maintenance Manual, “Maintenance Interval
Schedule”.
• Fill the fuel tank in order to help prevent
accumulation of moisture in the fuel. Do not overfill
the fuel tank.
Note: Only use the antifreeze coolant solutions that
are recommended in Special Publication,
SEBU6251, “Caterpillar Commercial Diesel Engine
Fluids Recommendations”. Failure to follow the
recommendations in Special Publication, SEBU6251,
“Caterpillar Commercial Diesel Engine Fluids
Recommendations” can cause engine damage.
• Allow the engine to cool. Check the coolant level.
Maintain the cooling system at 13 mm (0.5 inch)
from the bottom of the pipe for filling.
• If freezing temperatures are expected, check the
coolant for proper antifreeze protection. The
cooling system must be protected against freezing
to the lowest expected outside temperature. See
Special Publication, SEBU6251, “Caterpillar
Commercial Diesel Engine Fluids
Recommendations”. Add the proper coolant/water
mixture, if necessary.
• Perform all required periodic maintenance on the
generator. The generator maintenance is outlined
in the Operation and Maintenance Manual that is
supplied with the generator.
90
SEBU7125-13
Operation Section
Engine Stopping