6
Maintenance
Regarding Filter Capacity
1. Exact lter capacity varies in proportion to the amount of water
used and the level of impurities in the water being processed. For
contaminants reduced through physiochemical adsorption, the lter
capacity is 750 gallons. For contaminants reduced through mechanical
ltration, capacity claims are inapplicable due to broad variations in the
quality and quantity of physical matter in the drinking water. Excessive
physical matter will cause the CB-VOC to clog, diminishing ow rate
but reducing the contaminants from the resultant water stream.
2. For optimum performance and to maintain the lifetime warranty on
your system housing, it is essential that the lter be replaced when the
rst of the following occurs:
a. Annually
b. When the system is near or has reached its rated capacity
c. When the ow rate diminishes
d. When the lter becomes saturated with bad tastes and/or odors
Removing the Old Filter Cartridge
1. Before opening the CB-VOC housing, place a pan or basin beneath
the housing.
2. Stop the water supply and relieve the water pressure in the CB-VOC.
3. If the system is mounted on a bracket, remove the system from the bracket.
a. Tilt the top of the system toward the wall.
b. Slide the locking V-Band up and into
the upper bracket notch.
c. Slide the system out of the bracket.
4. With the CB-VOC housing in an upright position, unscrew the black
knob on the Locking V-Band by turning it counter-clockwise.
5. With the black knob removed, spread the Locking V-Band apart and
let it drop off the bottom of the CB-VOC. Carefully set it aside.
v-band
v-band
bracket