LIMPIDO Z : QUICK START
QUICK START OF THE DEVICE :
HIGH OR LOW SALT LEVEL WARNINGS & BACKWASH
ENTER ELECTROLYSE MENU
For a quick and efficient start of the electrolysis system, use the mode Production=ON. This mode will allow to
control the device together with the filtration system.
ENTER pH MENU
Set regulation on pH Dosage ph = pH- to bring pH down.
Set regulation on pH Dosage ph = pH+ to bring pH up.
The pH=ON mode is a continuous functioning mode which must be used only for pump priming.
NEVER LEAVE THIS SETTING ON, otherwise the pH bottle would empty quickly.
The device is provided with a safety on pH injection, which allows to set a maximum daily volume not to be
exceeded. For example, in a 40m3 pool, a daily dose of 0.3 litre/24h is enough. This setting can be done in the
pH menu: V/24h=0.3L.
SHORT FILTRATION POWER CUTS :
Warning : short power cuts (less than 1 minute) on the filtration pump or on 230V may lead to default of
the device. This default stops chlorine production but is not harmful to the device
When you face « lack of salt » of « high salt level », cut off the device for 5 minutes, then restart
the device after checking the electrolysis setting is not OFF. This operation can be enough to remove
the warning. If the default remains, check the real salt level into the pool as described in page 6 of the
user’s guide.
IN CASE OF BACKWASH :
Turn off the device while backwashing the filter. The device should remain turned off during backwash
(5 minutes)
For a correct setup of the probes, use
ZELIA-POD and connect the ground socket
of the ZELIA-POD on a ground rod which
is independent from the safety ground
equipment of the house. This independent
ground system must be as good as pos-
sible in order to increase the efficiency of
the probes (reading and lifetime).
USING INSTRUCTIONS
Injection pH
pH injection
Sonde pH
pH probe
Sonde ORP
ORP probe
PoolTerre intégré
Earthing device
Z3
Only
For a more precise electrolysis, use the mode Production=REG which will allow to control chlorine
production according to pool RedOx. See the instructions leaflet, on page 12 to buffer the RedOx probe and
to set the RedOx set value
Question and Answer IconNeed help?

Do you have a question about the ccei LIMPIDO Z and is the answer not in the manual?

ccei LIMPIDO Z Specifications

General IconGeneral
Brandccei
ModelLIMPIDO Z
CategoryWater Filtration Systems
LanguageEnglish

Summary

Quick Start of the Device

Electrolyse Menu Configuration

Configure electrolysis mode (Production=ON/REG) and RedOx settings for efficient chlorine production and pool control.

pH Menu Configuration

Set pH regulation (pH-/pH+) and pH=ON mode for pump priming. Monitor daily pH injection volume.

Salt Level Warnings and Backwash Procedures

Impact of Power Cuts

Short power cuts may cause a default, stopping chlorine production but not harming the device.

Handling Salt Level Warnings

Restart device after 5 min for salt warnings. Check salt level if warning persists.

Backwash Procedure

Turn off the device during backwashing the filter for 5 minutes.

Using Instructions and Probe Setup

Probe Installation and Grounding

Correct probe setup requires ZELIA-POD and an independent ground rod for optimal efficiency and lifetime.

Flow Switch Control

Flow Detector Initial Check

Verify flow detector integration and function at first start-up.

Flow Light Indicator

Ensure the flow light appears on screen when the filtration system is active.

Chlorine Production Light

Confirm the production light activates when chlorine production is turned on.

Checking Flow and Production on Stop

Verify flow and production lights disappear when filtration stops; check for blockages.

Restarting Filtration and Lights

Restart filtration after a pause and re-check flow and production lights for proper function.