FUNCTIONAL DESCRIPTIONS AND SPECIFICATIONS CHAPTER 2
The SURETEST always returns to the default menu from the measurements mode in the event there is no
selection / input by the User. This serves as a reminder for more (input) measurements.
Setup Mode
The following Selections are available:
1. SELECT MODE
2. SELECT UNIT
3. SELECT LANGUAGE
4. MANUFACTURER’S DEFAULTS
5. AUTO SETTINGS
6. EDIT LIMITS
7. CLOCK ADJUST
8. CALIBRATION
9. EDIT PARAMETERS
10. CDI INTERNAL
11. ABOUT
1. Select Mode
Selects either TRACK, PEAK HOLD, FIRST PEAK, or POWER mode.
• TRACK : In this mode, the SURETEST continually makes Torque Measurements.
• PEAK : The SURETEST makes Torque Measurement at the Highest Peak.
• 1.PEAK : The SURETEST makes Torque Measurement at the First Peak.
• POWER : The SURETEST makes Torque Measurement at the Highest Peak at a faster rate.
2. Select Unit
Selects the following Torque units on LCD display:
Nm, dNm, cNm, mkg, ft-lb, in-lb, in-oz .