QUICK START GUIDEQUICK START GUIDE
A22K 2-DOOR / 4-READER CONTROLLERA22K 2-DOOR / 4-READER CONTROLLER
LAN or WAN
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
BUZ GRN RED D1 D0 GND 12V BUZ GRNRED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
BUZ GRN RED D1 D0 GND 12V BUZ GRNRED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
The ATRIUM A22K controller includes an embedded web server.
You can connect directly using your browser (PC, smartphone or
tablet) and do basic conguration, such as add / delete a user,
create and assign access levels to a user, etc. Simply install the
“ATRIUM Finder” application (Apple Store or Google Play) and
visit the CDVI website for all video tutorials on basic conguration
via the embedded web server:
https://www.cdvi.ca/cdvi-academy/videos/
Use the FREE ATRIUM software for advanced conguration
(PC only).
A22K FULL MANUAL
Scan the QR Code with your smartphone
for the full A22K manual
ATRIUM BASIC CONFIGURATION
Scan the QR Code with your smartphone for
the ATRIUM system configuration quick start guide
or visit CDVI website to download the manuals : www.cdvi.ca
POWER UP THE A22K CONTROLLER
VIDEO TUTORIALS ON ATRIUM SYSTEM CONFIGURATION
8
9
PLAN YOUR A22K NETWORK CONNECTIVITY
500 door system (100 doors connected IP + 400 doors connected RS485)
1
“MASTER”
CONTROLLER
The “Master” controller
manages up to forty nine (49)
“Sub-Controllers”.
(100 doors fully IP)
IP CONNECTIVITY
Out of the box the A22K is ready for IP connectivity, fty (50) A22K per account.
If you have more than one A22K controller per account, one must be set as
the “Master” controller to manage the others. These forty-nine (49) others are dened as “Sub-Controllers”.
RS485 CONNECTIVITY
An A22K can be set as an “Expander”. Up to four (4) can be connected to the
RS485 network (orange connector) of the “Master” and each “Sub-Controller”.
A22K “Master” or “Sub-Controllers”
RS485 port (orange connector).
A22K set as “Expander” A22K set as “Expander” A22K set as “Expander” A22K set as “Expander”
IP Network
Maximum 300 ft (100 m)
How to set an A22K as an “Expander”
On power OFF, move the “Module Type”
jumper setting to the two pins closest to “EX”.
DO NOT use IP connection
when an A22K is set as an
“Expander”.
Do not connect to a receptacle
controlled by a switch.
Simply plug the power cord into an AC electrical outlet.
LED on door metal enclosure illuminates green
when power is established.
Universal Power Supply specications:
Input: 120-240 VAC, 1.2 A, 50 Hz/60 Hz
Output: 24 VDC @ 2.5 A
“SUB-CONTROLLERS”
Up to forty-nine (49) A22K dened as “Sub-Controllers”.
EX CT
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+LK2-TMPC2 12VREX2
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
+12V DC
A+
B-
Input 1
Input 2
Output 1
Output 2
INPUT
POWER
SUPPLY
RS485
LOCAL
BUS
ETHERNET
PORT
SYSTEM STATUS
EXTRA
INPUTS/
OUTPUTS
ETHERNET LOCAL BUS LOCK 1 & 2
JUMPER SETTING
STATUS
24V DC INPUT/
BATTERY/
MODULE TYPE
BATTERY
BACKUP
READER DOOR 1
INPUT
DOOR 1
LOCK
DOOR 1
LOCK
DOOR 2
INPUT
DOOR 2READER DOOR 2
ENCLOSURE
TAMPER
SWITCH
INPUT
BUZ GRN RED D1 D0 GND 12V BUZ GRN RED D1 D0 GND GNDC112V 12VREX1 GND GND C1 NO1 NC1LK1+ LK1- C2 NO2 NC2LK2+ LK2-TMPC2 12VREX2
Use twisted pair wiring
for RS485 connection
(1 pair for ground and 1
pair for A+ B-)
Maximum 4000 ft
(1220 m)
Communication between the
“Master” controller and
“Sub-Controllers” is
established via TCP/IP ONLY.
AES256
ENCRYPTION