ENGLISH ENGLISH
Humidier produces
an unusual smell
Humidier is new.
Take out water tank, open cover, let
it stay 12 hours in cool position.
Dirty water or water sitting
too long.
Clean water tank, ll with clear
water.
Residual smell from diusing
aroma oil on the aroma
cotton.
Remove the aroma cotton, rinse it
under clean water and allow it to
dry.
Humidier makes
a loud or unusual
sound
Resonant in water tank when
water is too low.
Fill water into water tank.
Humidier is on an unstable
surface.
Move the humidier to a stable at
surface.
Water tank is positioned
incorrectly.
Turn o and unplug the humidier,
then align the water tank cover with
its respective opening in the inner
chamber.
Humidier is malfunctioning.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
The humidication
capacity is too low
There is natural or articial
air replacement in the room
which interfere the increase
of %RH.
Check if doors and windows are
closed.
Check if there is no air conditioning
working in the room.
The air inlet grids and nozzle
could be blocked.
Remove any blocking items from
the grids and the nozzle.
Too much scale in the water
basin.
Clean transducer.
The humidity selected rate is
too low.
Increase mist output speed.
Increase humidity setting rate.
Water is too dirty or water
kept too long in the tank.
Clean water tank, change to fresh
clear water.
The ambient
humidity is too high
Humidier is working in
Continuous mode.
Change the mode.
The humidity target is too
high.
Select a lower %RH target.
Room is not well-ventilated
Open a window to ensure proper
air ow for the humidier or move
the humidier to a better ventilated
room.
Excess water tank has
spilled while lling the water
tank or replacing the water
tank back onto the base.
Wipe o excess water from the
top and bottom of the base before
replacing the water tank.
There is
condensation in the
room
The room temperature is
too low.
Heat the room up.
The mist suddenly
stops coming out
Programmed timer period
has run out.
Turn humidier on.
The water shortage indicator
is on.
Rell water tank.
The target humidity level is
reached.
Incorrect humidity
level is being
displayed.
Room is larger than the
eective range of the
humidier.
Move the humidier to a room
which is with suitable room size.
Moisture has built up inside
of the humidity sensor.
Turn o the humidier and allow
the humidity sensor to completely
air dry before resuming use.
The nozzle is facing the
direction of the humidity
sensor.
Turn the nozzle so that it is facing
away from the humidity sensor.
Humidity sensor is broken of
defective.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.