thinner, or other solvents, as these can scratch and damage the tank and cause water
leakage.
- Do not immerse the product in water or other liquids.
Cleaning the lter. Fig. 12
- If the lter is clogged with dust, the eectiveness of the air conditioning will be reduced.
Make sure to clean the lter once every two weeks.
- Cleaning the upper lter frame
- Unscrew the screw attached to the lter at the rear with a screwdriver and remove the
lter.
- Put the lter screen into warm water with neutral detergent (about 40 ºC / 104 ºC) and
dry it in the shade after rinsing clean. Make sure it is completely dry before reattaching it.
Replacing batteries
The remote control is powered by two AAA batteries. If the remote control does not respond,
replace the batteries as follows:
1. Put the remote control face down and slide the tab outwards.
2. Remove the batteries.
3. Insert the batteries paying attention to polarity.
Storage
- Store the device in well ventilated areas.
- Unscrew the drain cap, unplug the water plug, and discharge the water in the water tank
into other water containers or directly tilt the body to discharge the water into other
containers.
- Turn on the appliance, adjust it to low-wind ventilation mode, and maintain this state until
the drainage pipe becomes dry. This way, you will keep the inside of the body in a dry state
and prevent it from mildewing.
- Turn o the appliance, unplug the power plug, and wrap the power cord around the
wrapping post. Install the water plug and the drain cap.
- Remove the exhaust pipe and keep it properly.
- Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it
out of the reach of children, and take dust control measures.
- Remove batteries of the remote control and keep them properly.
- Ensure that the body is placed in a dry place and keep all machine components properly.
Maintenance
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certicate from an industry-accredited assessment authority, which authorises
their competence to handle refrigerants safely in accordance with an industry recognised
assessment specication.
7. TROUBLESHOOTING
Problems Possible causes Possible solutions
The air
conditioning
does not
work.
There is no electricity. Turn it on after connecting it to a socket
with electricity.
The full-tank indicator will
ash.
Discharge the water inside.
The room temperature is
too low or too high.
It is recommended using the appliance in at
the temperature of 7-35 ºC.
In cooling mode, the room
temperature is lower than
the set temperature; in
heating mode, the room
temperature is higher than
the set temperature.
Change the set temperature.
In dehumidication mode,
the room temperature is
very low.
The appliance is in a room with a
temperature below 17°C.
The cooling
eect is not
good
There is direct sunlight. Pull the curtain.
Doors or windows are
open; there are a lot of
people; or in cooling mode,
there are other sources of
heat.
Close doors and windows.
The lter screen is dirty. Clean or replace the lter.
The air inlet or outlet is
blocked.
Clear obstructions.
The device
makes a lot
of noise
The air conditioning is not
placed on a at surface.
Put the air conditioning on a at and hard
place (to reduce noise).
Compressor
does not
work.
There is frost. Wait for 3 minutes until the temperature is
lowered, and then restart the appliance.
Protection against
overheating system is
activated.