THIS RECHARGEABLE POWER TANK IS POWERED BY SEALED LEAD-ACID BATTERY, ONE PC (12V 17 Ah/20 HR).
- Make sure the POWER TANK is in the "OFF" position
before removing battery. (Fig. 21)
- Make sure the POWER TANK is disconnected from charger
which must be OFF from the electric supply. (Fig. 23)
- Remove the spotlight by loosening the screw.
- Face the POWER TANK down and open into 2 halves by
unscrewing screws counterclockwise. (Fig. 22)
- Cut wires to remove battery.
DISCONNECTED
Fig.23
Fig.22
Fig. 21
1. NO LED INDICATOR ( LOW or CHARGE )
WHEN SWITCH IN 'ON' POSITION
2. NO LED INDICATOR ( FULL or CHARGE )
WHEN RECHARGING.
3. DC-12V OUTPUT DOESN'T WORK
WHEN SWITCH IN 'ON' POSITION .
4. DC 3, 6, 9V OUTPUT DOESN'T WORK
WHEN SWITCH IN 'ON' POSITION.
CIRCUIT BREAKER CUT OFF CIRCUIT
CIRCUIT BREAKER CUT OFF CIRCUIT
CIRCUIT BREAKER CUT OFF CIRCUIT
FUSE WAS BROKEN
RESET THE CIRCUIT BREAKER
ACCORDING TO THE INSTRUCTION
REPLACE THE FUSE ACCORDING TO
THE INSTRUCTION
RESET THE CIRCUIT BREAKER
ACCORDING TO THE INSTRUCTION
RESET THE CIRCUIT BREAKER
ACCORDING TO THE INSTRUCTION
PROBLEM
POSSIBLE
SOLUTION
HOW TO USE THE POWER TANK TO START A VEHICLE:
- The ON/OFF switch can be set to"ON" or "OFF" position for the starting aid function.
- Connect the POSITIVE pole (+) of the POWER TANK to the POSITIVE pole (+) of the vehicle battery.
- Connect the NEGATIVE pole (-) of the POWER TANK to the NEGATIVE pole (-) of the vehicle battery.
- Leave the POWER TANK connected to the vehicle battery for around 20 minutes.
- After approximately 20 minutes, disconnect the jumper cable from the NEGATIVE pole (-) of
the vehicle battery.
- Then disconnect the jumper cable from the POSITIVE pole (+) of the vehicle battery.
- This partial charge should be sufficient to start the vehicle.
- The POWER TANK need to be recharge after giving this starting aid.
Fig.24
Batteries :
Operation Temp. :
DC 12V Output :
DC 3,6,9V Output :
Weight :
Dimension :
One Pcs. 12V / 17Ah Rechargeable Sealed Lead-Acid Battery.
ooo o
32 F to 86 F / 0 C to 30 C
D.C. 12V / 10A output with 15A CIRCUIT BREAKER. Negative Ground.
D.C. 3,6,9V / 1A output with 2 A FUSE Negative Ground.
20 lbs. / 9.1 Kg. (Approx.)
355 H x 345 W x 132 D / 13.9" x 13.6" x 5.2" (Approx.)
WARNING:
- The Fuse and Switch is not function on the connect ( + ) ( - ) pole, current is directly flow from the battery, Once the jumper
cables is connected, NEVER allow the cables touch together or left on the same metal surface, these will result in short
circuit and may start a fire.
- NEVER ATTEMPT TO START THE VEHICLE WITH THE POWER TANK CONNECTED.
TO REMOVE BATTERY FOR DISPOSAL
TROUBLESHOOTING
STARTING AID FOR MOTOR VEHICLES
CAUTION: THERE MAY BE AN ELECTRIC SHOCK.
- The jumper cable with the battery clips is located on the rear of the unit. (Fig. 24)
- Do not take the jumper cables out of the unit unless you need them.
- The POWER TANK can only be used as a starting aid when the vehicle's battery is only partially
discharged. Thus, only a limited capacity can be transferred into the vehicle's battery.
SPECIFICATIONS
ADAPTER
CHARGE
PLUG
BUILT-IN JUMPER CABLE
WITH CLAMP
DC POWER
CORD
NOTE:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS
TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.

Questions and Answers

  • C
    Carly HoldenJul 27, 2025
    Why no LED indicator when recharging Celestron POWER TANK 17?
    • A
      Ashlee ParkerJul 27, 2025
      If you notice that there's no LED indicator (neither FULL nor CHARGE) when you're recharging your Celestron Power Supply, the circuit breaker might have tripped. You should reset the circuit breaker as described in the instructions.
  • E
    ericjacksonAug 6, 2025
    What to do if DC-12V output doesn't work on Celestron POWER TANK 17?
    • L
      Lisa SchultzAug 6, 2025
      If the DC-12V output on your Celestron Power Supply isn't working when the switch is in the 'ON' position, it's likely that the circuit breaker has cut off the circuit. To resolve this, reset the circuit breaker following the provided instructions.
  • M
    Marilyn BurkeAug 16, 2025
    What to do if DC 3, 6, 9V output doesn't work on Celestron POWER TANK 17 Power Supply?
    • T
      Tracy HuffmanAug 16, 2025
      If the DC 3, 6, 9V output on your Celestron Power Supply is not working while the switch is in the 'ON' position, the fuse may be broken. Replace the fuse according to the instructions.

Summary

TO REMOVE BATTERY FOR DISPOSAL

TROUBLESHOOTING

STARTING AID FOR MOTOR VEHICLES

SPECIFICATIONS

RECHARGE

AC RECHARGING

Procedure for recharging the unit using an AC adapter.

DC RECHARGING

Procedure for recharging the unit using a DC adapter.

STORAGE

OPERATION

Power Supply

Connecting devices to the appropriate output receptacle.

Flashlight

Operating the built-in and detachable flashlight.

Radio

Operating the built-in radio functions.

Emergency Siren

Operating the emergency siren function.

REPLACEMENT

FLASHLIGHT BULB

Instructions for replacing the flashlight bulb.

SPOTLIGHT BULB

Instructions for replacing the spotlight bulb.

CIRCUIT BREAKER

Procedure for resetting the circuit breaker.

FUSE

Procedure for replacing the fuse.

Celestron POWER TANK 17 Specifications

General IconGeneral
Capacity17 Ah
Output Voltage12V DC
Battery Capacity17 Ah
LED LightYes
ChargingAC/DC adapter input
Battery TypeSealed Lead Acid (SLA)