20V3.15.22
III.OperatingInstructions
Overview
Testthecoolingunittomakesureitisworkingproperlybeforeinstallingthecoolingunit(referto
theinstructionsatthebeginningofthepreviouschapter.)
CellarPro cooling units are designed to maintain optimal conditions for wine storage and aging.
Theseconditionsincludesteady,cooltemperatures,highhumidity,minimalvibrationandlight,and
cleanair.
ThesettingsonyourCellarProcoolingunithavebeenpresetandoptimizedbythefactory.Before
changinganysettingsbelow,werecommendwaiting14daystoallowthecoolingunitto“breakin.”
Thecoolingunitisdesignedtocoolthecellargentlywithoutstrippingmoistureoutofthecellar
environment.Therefore,itisnotuncommonforthecoolingunittorunnonstopforuptoaweek
initially,dependingonthetemperatureinsidethecellar,thesizeofthecellar,andthetemperature
oftheambientenvironment.Oncethecellarhasreachedequilibrium,itisnormalforthecooling
unittorunasmuchas75percentofthetime.
CellarProcoolingunitsaredesignedtomaintainoptimaltemperaturesforstoringandagingfine
wine.CellarProcoolingunitsarenotdesignedtomaintaintemperaturesforservingwine,which
tendtobemuchcolderthanstoragetemperatures,especiallyservingtemperaturesforwhiteand
sparklingwines.
CellarProcoolingunitsmustbeused,stored,movedand/orshippedintheuprightposition.Be
carefulwhenturningtheunitonitsside.TheunitNEVERshouldbeturnedupsidedown.
The cooling system is programmed with a 3‐Minute Delay at Startup to protect its internal
components.
TemperatureControl
CellarPro cooling units are designed to turn “on” when the air temperature passing over the
evaporator coils inside the cellar exceeds the Minimum Set Point plus the Temperature
Differential, and turn “off” when the temperature drops below the Minimum Set Point. For
example,iftheMinimumSetPointis58
°
FandtheTemperatureDifferentialis4
°
F,thecoolingunit
willturnonwhenthetemperaturerisesabove62
°
Finsidethecellar,anditwillturnoffwhenthe
temperaturefallsbelow58
°
F.Inthisexample,theaveragetemperatureinsidethecellarwillbe
60
°
F.
BasicOperation
ThetemperatureinsidethecellarcanbeincreasedordecreasedbychangingtheMinimumSet
Pointassummarizedbelow,anddetailedlaterinthischapter.
• Pressthe“Set”buttonforthreesecondsuntilthesnowflakeor°Fblinks
• Press“Up”or“Down”button