22V3.15.22
(2)FanSpeedSelectorSwitch(Low/Med/High):Thecoolingunitfansoperateon3speedsettings:
Low,Medium,andHigh.Foroptimumsoundandenergyefficiency,selectthelowestfanspeed
thatwillmaintainthedesiredcellartemperature.Highspeedisrecommendedforinitialcellarpull
downandextremetemperatureconditions,andisrequiredforductedinstallations.
(3)CondensateEvaporatorSwitch(OFF/ON):Wheninthe“on”position,theswitchwillilluminate
indicating the condensate evaporator is energized to remove moisture collected in the unit’s
condensatedrainpan.Theswitchlightmaycycleoffandonindicatingalowmoistureenvironment.
Ifthis condition is observed,orifno condensate is presentattheoverflow, the switch maybe
turned“off”toreduceunitenergyconsumption.Forinitialcellarpulldownorinhighhumidity
environments,theswitchshouldbesetto“on”.
(4)PowerSelectorSwitch(Front/Rear):Theunitispoweredbyinstallingtheprovidedplugcordin
thefrontorrearoftheunit.Tousethefrontreceptacle,setswitchto“Front”andpluginthecord
atthefrontrightsideoftheunit(location#6).Tousetherearreceptacle,setto“Rear”andplugin
thecordattherearoftheunit(location#7).
(5)BottleProbeJack(BottleProbe):Plugintheremotebottleprobe(soldseparately)tocontrol
thecellarbyliquidtemperatureratherthanairtemperatureinsidethecellar.Disconnectingthe
probe will automatically return the controlto air temperature. When using a bottle probe, the
Temperature Differential will need to be adjusted to 1 degree as shown in the “Advanced
Operation”instructionsbelow.
(6/7)GroundedPowerReceptacle:Onereceptacleislocatedonthefrontright(#6),andoneon
therear(#7).Usethereceptaclethatismostconvenientfortheinstallation.Enablethereceptacle
bysettingthepowerlocationswitch(#4)to“Front”or“Rear”.