7V3.15.22
Placement
CellarPro3200and4200SeriescoolingunitsaredesignedtobeinstalledTHROUGHTHEWALL,so
thattherearandthefrontofthecoolingunitDONOTSHARETHESAMEAIRSPACE.
Therearofthecoolingunitmustbeinstalledinaspacethatisatleastaslargeasthewinecellar
unlesstherear intake and exhaustare ducted. Both the front and the rear of the cooling unit
requireaminimumclearanceof8inches.
TheseunitsalsocanbeplacedcompletelyINSIDEorOUTSIDEthecellarwhenusedincombination
withourductkits.
AmbientEnvironment
3200VSi‐ECX/4200VSi‐ECX‐designedforinternaluseonly(ieshelteredfromoutdoorweather),
therearoftheunitcanbeexposedtotemperatureconditionsrangingfrom40to110°F.
3200VSx‐ECX / 4200VSx‐ECX–designedforshadedexternaluse,therearoftheunitcanbe
exposedtotemperatureconditionsrangingfrom40to110°F.
PLEASENOTE:
Ourunitswerenotdesignedfor,andourwarrantydoesnotcoverdamagefrom,marineexposure
(within5milesoftheocean).Inthese environments, youwill need anappliedcoating,such as
Insitu®,toprotectagainstcorrosionthatiscommonincoastalregions.
Withour(optional)compressorheater,allofourcoolingunitscanbeusedinenvironmentsdown
to 20°F, and with our (optional) fan cycling switch, all of our cooling units can be used in
environmentsdownto‐20°F.
Heat
CellarProcoolingunitsarenotdesignedtoheatthecellarspace,soiftemperaturesinsidethecellar
dropbelowproperwinestoragetemperatures,thecoolingunitcannotcreateheatinsidethecellar.