4
1000V/DCV. ,750V/ACV
Sampling Rate: 2.5 times per second.
Zero Adjustment: Automatic adjustment.
Over Range Indicator: OL of highest digit is displayed.
Low Battery Indication: The is displayed w hen the battery
Voltage drop below the operating voltage.
Operating Temperature: C to 40ºC (32ºF to 104ºF) and Humidity
below 80% RH
Storage Temperature: -10ºC to 60ºC (14ºF to 14F) and Humidity
below 70% RH
Power source: DC9V (6x1.5V Size “AA battery or Equivalent)
Dimensions: 200(L) x 92(W) x 50(H) mm
Weight: Approx 700g include battery
Accessories: Test leads, 6pcs battery, Carrying case, manual.
1-2 Electrical Specifications
Accuracies are specified in the w ay:
±(…% of reading +…digits) at 2C±C,below 80% RH.
OHMS
Range
Resolution
Accuracy
Max. open
Circuit Voltage
Overload
Protection
40.00Ω
0.01Ω
+(1.2%+3)
5.8V
250Vrms
400.0Ω
0.1Ω
5.8V
Continuity Beeper
Range
Resolution
Max.open
Circuit
Voltage
Overload
Protection

Related product manuals