Technical instructions CONTROLLER - CPREG-Touch
95
Errors
E8
FAN MALFUNCTION
Possible cause: The RPM sensor does not see the fan
rotation.
Boiler status: Currently goes to OFF mode.
Troubleshooting: Check for the possible rotation of the RPM
sensor, due to the arrangement of the fan bearings (to see if
the sprocket is free to rotate), due to the input of the external
body into the fan coil, due to the release of the thermal
protection of the fan (after cooling the 30°C fan can be started
again) due to too low network voltage.
E9
BACKFILLING SUPPLY
TUBE WITH PELLETS
Possible cause: fulfilling the pellet filling tube with pellets
Boiler status: Currently goes to OFF mode.
Troubleshooting: Check the fullness of the burner grate,
burner furnace, boiler furnace, and chimney, whether the
burner grate is well positioned in the burner (is not installed ON
the el. heater) - valid for CPPL 14-50), whether pellets are not
too humid, inadequate dimensions or quality pellets (for these
burner diameters 6 mm), possible holes on the flexible tube
pipe, too much pellet delivery / low rpm, incorrectly loaded
filling parameters, incorrect combustion air.
E9_1
BACKFILLING SUPPLY
TUBE WITH PELLETS
Possible cause: Filling the flexible tube with pellets - variant_1
- when it is in operation reduced pellet supply over a period of
time in which it failed to return to the normal filling regime with
fulfilling (factory only active on CPPL 90)
Boiler status: Currently goes to OFF mode.
Troubleshooting: Check the fullfillness of the burner
gate,burner furnace,boiler furnace, and chimney , whether the
burner grate is well positioned in the burner (is not installed ON
the el. heater) - valid for CPPL 14-50), whether pellets are not
too humid, inadequate dimensions or quality pellets (for these
burner diameters 6 mm), possible holes on the flexible tube
pipe, too much pellet delivery/low rpm, incorrectly loaded filling
parameters, incorrect combustion air.
E9_2
BACKFILLING SUPPLY
TUBE WITH PELLETS
Possible cause: Filling the flexible tube with pellets - variant_2
- when it is in operation reduced pellet supply over a period of
time in which it failed to return to the normal filling regime with
fulfilling (factory only active on CPPL 90)
Boiler status: Currently goes to OFF mode
Troubleshooting: Check the fullness of the burner gate,
burner furnace, boiler furnace, and chimney, whether the
burner grate is well positioned in the burner (is not installed ON
the el. heater) - valid for CPPL 14-50), whether pellets are not
too humid, inadequate dimensions or quality pellets (for these
burner diameters 6 mm), possible holes on the flexible tube
pipe, too much pellet delivery/low rpm, incorrectly loaded filling
parameters, incorrect combustion air.