1. What is G-SPEAK ULTRA?
2. Important Safety Instructions
3. Glossary of Terms
5. Product Identication
6. Product Dimensions
5.1. G-SPEAK ULTRA
6.1. G-SPEAK ULTRA
5.2. Calling Module
6.2. Calling Module
7. Functional Feature Highlights
8. Device Layout and Wire Connections
9. LCD Interface
4. Technical Specications
The G-SPEAK ULTRA promotes the ultimate in convenience and peace of
mind by combining wireless GSM technology with CENTURION’s futuristic and
stylish ULTRA interface. Infused with the DNA of innovation, the G-SPEAK
ULTRA allows wireless communication between the user and the intercom gate
station, eectively turning the user’s phone into the intercom handset.
Filter Time: Filter Time determines how long an input event (Rising or Falling
Edge) must be present before it is recognised, i.e. an SMS or email is sent, or
a missed call is initiated. The time is set in increments of one second and the
default is 0.
Blanking Time: Blanking Time determines how long the unit will wait
between events before it will recognise the next event.
Hang Time: The time for which the call remains connected after a DTMF
event.
Any Number Mode: When enabled, this useful feature allows any number
to activate the module’s outputs, irrespective of whether they are learned into
memory. A typical application would be an event such as a wedding where
many guests need to be given temporary access. Instead of manually learning
in a 100 guests and then having to delete them again after the occasion,
the administrator can simply enable Any Number Mode and disable it again
afterward.
DTMF: Dual Tone Multi-Frequency signaling. This is used for
telecommunication signaling over analogue telephone lines in the voice-
frequency band between telephone handsets and other communication devices
and the switching centre. This allows the user to press a number on his or her
mobile handset to switch any of the outputs on the G-SPEAK ULTRA.
Channel: An electrical gateway implemented as a physical terminal on the
G-SPEAK ULTRA that provides the external interface to Input or Output signals
Called Party: When one of the Call Buttons on the Calling Module is pressed,
the Called Party is the person or persons who receives/answers the call on
their mobile phone or landline handset.
Calling Module: This can be seen as similar to a traditional intercom
gate station or entry panel that resides outside of the property and is the
component of the G-SPEAK ULTRA system that is used to dial through to and
communicate with Voice Phones.
GSM Controller: A module using 2G GSM (Global System for Mobile
Communications) technology to communicate wirelessly with GSM-enabled
handsets, allowing both audible communication and monitoring and switching
of Inputs and Outputs.
Voice Phone: A Voice Phone pertains specically to the intercom functionality
of the G-SPEAK ULTRA system, and is any learned-in phone with the ability to
communicate audibly with the Calling Module, but is also capable of activating
any of the Outputs during a call using DTMF signaling.
Switch Phone: A Switch Phone is a learned-in phone that is capable of
exercising some inuence upon the Outputs of the controller via GSM switching
and does not necessarily possess Voice Phone functionality, though it can be
learned in for both.
Access Number Proles
The access number conguration proles eliminates the hassle of conguring
input and output permissions and notications every time that a new number
is added.
Intelligent Gate Status Monitoring
With seamless integration with CENTURION gate motors, the G-SPEAK ULTRA
will let the user know when his or her gate has been left open, or is in any
other state specied by the user through intelligent monitoring of the gate
motor’s status output. Adjustable Filter settings mean that the user can specify
under which conditions they are notied about a particular gate status, for
example if the gate has remained open for longer than 20 seconds.
Supplied with activated SIM card (South Africa only)
All G-SPEAK ULTRA units are supplied with an activated Vodacom SIM card
(South Africa only). Airtime can be purchased via G-WEB (South Africa only).
Monitoring and alerting
The device can be congured to monitor up to four separate electrical devices,
such as a home alarm or even a water reservoir. It could send the user an
SMS, give a missed call or even send an email, letting the user know if the
house alarm is on or o or a reservoir is full or empty. When congured as
inputs, the unit’s four individually-congurable channels can be congured
to react to Rising Edges, Falling Edges, or both, which makes it ideal for
monitoring variable levels such as mains power. A single input can be used, for
example, to send a notication to users when mains power has failed, and the
same input can notify users once it comes back on, freeing up the other inputs
to take care of monitoring duties for other devices.
Control
When congured as outputs, the device’s dry contacts can be used to remotely
control electrical devices and appliances such as gate motors, alarms, geysers
and lights, to name but a few possible applications. Outputs can be activated
via missed call, SMS text message or by pressing a number on the user’s
phone’s touchpad.
Timed access control
(Weekly and Visitor) Set arrival and departure dates and times; guests will
only be able to activate the device’s outputs between these limits, aording
the user maximum security and aording guests maximum convenience. As a
special value-add developed specically with B & B owners in mind, customised
arrival and departure messages with welcoming messages, access instructions,
etc., can be sent automatically to guests and visitors.
Alternatively, set weekly recurring time-periods (for example 8am to 5pm,
Monday to Friday) during which users will have access to the system.
Outside of the congured time-periods, access will be denied.
Add the ability to map inputs to outputs, customise the input and output
notication messages and use the G-SPEAK ULTRA in advanced applications
and one has a powerful and convenient GSM-based monitoring and control
solution. Up to 20 separate text messages with up to ve scheduled outputs
can be congured.
Time-barring windows can be congured to block notications, activations or
specic access numbers.
Quick device associations
Devices can be associated to a G-WEB prole in a matter of seconds by simply
scanning a QR code with one’s smartphone and a third-party universal QR
scanner application.
Table 3 below lists the information shown on the dierent screens found
on the LCD interface. The left and right scroll buttons are used to toggle
between the dierent screens.
Easy access to diagnostics
This smart device provides intelligent feedback via a graphic user interface
displaying status, system information and diagnostic messages for the
complete ULTRA experience.
Smart hardware
An internal GSM antenna ensures healthier, more reliable network signal
strength without the frustration of trying to nd the optimal location to
mount the unit. If one needs to t the G-SPEAK ULTRA in a metal enclosure,
simply attach an external antenna to the onboard connector.
Time-barring per call button
Each call button can be individually time-barred. For example, the primary
button can be time-barred so that only the secondary call button works
during the evenings or early in the morning while the primary call button is
disabled.
1. Do not install this product near DOSS sensor inside gate motor housing or
near the remote receiver.
2. Do not install this product near any sensitive electrical components.
3. All installation, repair, and service work to this product must be done by a
suitably-qualied person.
4. Do not in any way modify the components of the system.
5. Do not install the equipment in an explosive atmosphere: the presence of
ammable gas or fumes is a serious danger to safety.
6. Do not leave packing materials (plastic, polystyrene, etc.) within reach of
children as such materials are potential sources of danger.
7. Dispose of all waste products like packing materials, according to local
regulations.
8. Centurion Systems (Pty) Ltd does not accept any liability caused by
improper use of the product, or for use other than that for which the
automated system was intended.
9. This product was designed and built strictly for the use indicated in
this documentation. Any other use, not expressly indicated here, could
compromise the service life/operation of the product and/or be a source of
danger.
10. Anything not expressly specied in these instructions is not permitted.
1. Fascia
2. External Antenna Cover
3. Main Unit
4. Mounting Plate
1. Back Cover / Mounting Panel
2. Voice Communication Terminals
3. Call Button 1
4. Call Button 2
5. Terminal Blocks
6. Navigation panel
7. LCD Screen
5. Microphone
6. Front Cover / Fascia
7. Speaker
This icon indicates tips and other information that could be useful
during the installation.
TABLE 1
TABLE 2
FIGURE 1
FIGURE 2
FIGURE 4
This icon denotes variations and other aspects that should be
considered during installation.
Supply Voltage Range 11-24V DC
Maximum Current Draw 300mA @ 12V DC
Input/output Current Rating 50mA (Open Collector)
Input Sense Voltage Range 0-24V DC (0-1.6V Low-input State,
5V-24V High-input State)
SIM Card Micro-format, Activated SIM
Card Supplied (South Africa only)
1, 2
Number of Congurable Input/
output Channels
4
Call Buttons on Calling Module 2
Call conrmation at Calling
Module
Yes
Speech volume Adjustable at Calling Module using Call
Buttons
Calling Module illumination Call Buttons and labels with back-lit
white LEDs
Memory Capacity 5000 Event logs
20 Access Proles
1 Custom Welcoming SMS Message for
New Access Numbers
20 Custom Output Activation SMS
Messages (From User to Device)
30 Custom Input Notication SMS/Email
Messages (From Device to User)
100 Visitor Time-barring Windows
(Windows are the periods between two
dates)
30 Generic Time-barring Windows
(Windows are weekly recurring)
10 Output Activation Schedules
(Schedules are weekly recurring)
3 Daylight Saving Periods
4 Input to Output Mapping
Congurations
Model Options GSM 2G:
850/900/1800/1900MHz (EDGE)
GSM 3G:
900/2100MHz (EDGE)
900/2100MHz (UMTS)
GSM 3G PENTA:
800/850/900/1900/2100MHz (UMTS)
microSIM
SIM Card
Optional: External Antenna
NOTE:
The Internal Antenna is
selected by default.
Scroll Left
Scroll Right
Enter /
Home
GND IO4 P4IO1 P1 P5IO2 P2 P6IO3 P3 VIN NEG
GND Ground
IO1 Input / Output 1 (Default: Output)
IO2 Input / Output 2 (Default: Output)
IO3 Input / Output 3 (Default: Output)
IO4 Input / Output 4 / Gate Status Input (Default: Output)
P1 Data Communication Line
P2 Data Communication Line
P3 Data Communication Line
P4 Data Communication Line
P5 Data Communication Line
P6 Data Communication Line
VIN Positive of Power Supply 12-24VDC
NEG Negative of Power Supply
Home Screen
Network Name or Phone Number Applicable
to Incoming / Outgoing SMS or Call.
IO Status Screen
Network Signal Strength
Connected to Internet
Device has Error Condition
Incoming SMS
Outgoing SMS
Outgoing Phone Call Events
Connected to G-WEB
Incoming Phone Call Events
1
3
4
2
2
3
4
1
5
6
7
7
5
6
FIGURE 3
73.6mm
114.4mm 33mm
G-SPEAK ULTRA
QUICK GUIDE
GSM-BASED INTERCOM SYSTEM
Centurion Systems (Pty) Ltd
www.CentSys.com
www.centsys.com
Doc number: 1265.D.01.0004_2
SAP Code: DOC1265D0104
Connect with us on:
facebook.com/centurionsystems
YouTube.com/centurionsystems
@askcenturion
Subscribe to the newsletter:
www.centsys.com/subscribe
Call Centurion Systems (Pty) Ltd
.
South Africa
Head Oce: +27 11 699 2400
Call Technical Support: +27 11 699 2481
from 07h00 to 18h00 (UTC+2)
E&OE Centurion Systems (Pty) Ltd reserves the right to change any
product without prior notice
All product and brand names in this document that are accompanied by the ®
symbol are registered trademarks in South Africa and/or other countries, in favour
of Centurion Systems (Pty) Ltd, South Africa.
The CENTURION and CENTSYS logos, all product and brand names in this
document that are accompanied by the TM symbol are trademarks of Centurion
Systems (Pty) Ltd, in South Africa and other territories; all rights are reserved.
We invite you to contact us for further details.
Centurion Systems is a Company of the
FAAC Simply Automatic Business Unit
138mm
110mm
18mm
74mm
Calling Module
Back / Mounting Panel 32mm
Input: Deactivated
(“E” = Input event reached)
Input: Activated (pulled to ground)
(“E” = Input event reached)
Output: O
Output: On (pulling to ground)
1. May not be used in devices other than G-ULTRA (South Africa Only).
2. Remains the property of Centurion Systems (Pty) Ltd. (South Africa Only).
Question and Answer IconNeed help?

Do you have a question about the CENTURION SYSTEMS G-SPEAK ULTRA and is the answer not in the manual?

CENTURION SYSTEMS G-SPEAK ULTRA Specifications

General IconGeneral
BrandCENTURION SYSTEMS
ModelG-SPEAK ULTRA
CategoryIntercom System
LanguageEnglish

Summary

What is G-SPEAK ULTRA?

Important Safety Instructions

General Safety Precautions

Guidelines for safe installation and use, covering component handling, environmental conditions, and product modification.

Glossary of Terms

Technical Specifications

Product Identification

G-SPEAK ULTRA Identification

Details for identifying the main G-SPEAK ULTRA unit, including its fascia and components.

Calling Module Identification

Details for identifying the G-SPEAK ULTRA Calling Module, including its front and back components.

Product Dimensions

G-SPEAK ULTRA Dimensions

Physical dimensions of the G-SPEAK ULTRA unit, shown with its back/mounting panel.

Calling Module Dimensions

Physical dimensions of the Calling Module, including its front and back panels.

Functional Feature Highlights

Access Number Profiles

Configuration profiles simplify adding and managing new access numbers and their permissions.

Intelligent Gate Status Monitoring

Monitors gate motor status, alerting users to events like gates left open.

Monitoring and Alerting

Device can monitor up to four electrical devices, sending alerts via SMS, missed call, or email.

Remote Control Capabilities

Outputs can be remotely controlled via missed call, SMS text message, or DTMF signals.

Timed Access Control

Allows setting specific arrival/departure dates/times or weekly recurring periods for access.

Quick Device Association

Devices can be quickly associated with a G-WEB profile by scanning a QR code.

Device Layout and Wire Connections

G-SPEAK ULTRA Layout

Identifies components of the G-SPEAK ULTRA main unit and terminal block connections.

Calling Module Layout

Identifies components of the Calling Module, including call buttons and communication terminals.

Terminal Block Connections

Details the wiring for input/output channels, data communication lines, and power supply.

LCD Interface

Configurations

Mounting Plate and Fascia Removal

Instructions for removing the main unit from its mounting plate and disassembling the fascia.

Installation Procedures

Guidance on mounting the G-SPEAK ULTRA unit and the Calling Module to walls or goose-necks.

Configuration Methods

Details on configuring the device via the G-WEB online interface and SMS commands.

Wiring Diagrams

Visual representation of the G-SPEAK ULTRA connections to external devices like gate controllers.

Related product manuals